-=encoding UTF-8
-
-=head1 NAME
-
-collectd-snmp - Documentation of collectd's C<snmp plugin>
-
-=head1 SYNOPSIS
-
-  LoadPlugin snmp
-  # ...
-  <Plugin snmp>
-    <Data "powerplus_voltge_input">
-      Type "voltage"
-      Table false
-      Instance "input_line1"
-      Scale 0.1
-      Values "SNMPv2-SMI::enterprises.6050.5.4.1.1.2.1"
-    </Data>
-    <Data "hr_users">
-      Type "users"
-      Table false
-      Instance ""
-      Shift -1
-      Values "HOST-RESOURCES-MIB::hrSystemNumUsers.0"
-    </Data>
-    <Data "std_traffic">
-      Type "if_octets"
-      Table true
-      Instance "IF-MIB::ifDescr"
-      Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
-    </Data>
-
-    <Host "some.switch.mydomain.org">
-      Address "192.168.0.2"
-      Version 1
-      Community "community_string"
-      Collect "std_traffic"
-      Interval 120
-    </Host>
-    <Host "some.server.mydomain.org">
-      Address "192.168.0.42"
-      Version 2
-      Community "another_string"
-      Collect "std_traffic" "hr_users"
-    </Host>
-    <Host "secure.router.mydomain.org">
-      Address "192.168.0.7"
-      Version 3
-      SecurityLevel "authPriv"
-      Username "cosmo"
-      AuthProtocol "SHA"
-      AuthPassphrase "setec_astronomy"
-      PrivacyProtocol "AES"
-      PrivacyPassphrase "too_many_secrets"
-      Collect "std_traffic"
-    </Host>
-    <Host "some.ups.mydomain.org">
-      Address "192.168.0.3"
-      Version 1
-      Community "more_communities"
-      Collect "powerplus_voltge_input"
-      Interval 300
-    </Host>
-  </Plugin>
-
-=head1 DESCRIPTION
-
-The C<snmp plugin> queries other hosts using SNMP, the simple network
-management protocol, and translates the value it receives to collectd's
-internal format and dispatches them. Depending on the write plugins you have
-loaded they may be written to disk or submitted to another instance or
-whatever you configured.
-
-Because querying a host via SNMP may produce a timeout multiple threads are
-used to query hosts in parallel. Depending on the number of hosts between one
-and ten threads are used.
-
-=head1 CONFIGURATION
-
-Since the aim of the C<snmp plugin> is to provide a generic interface to SNMP,
-it's configuration is not trivial and may take some time.
-
-Since the C<Net-SNMP> library is used you can use all the environment variables
-that are interpreted by that package. See L<snmpcmd(1)> for more details.
-
-There are two types of blocks that can be contained in the
-C<E<lt>PluginE<nbsp>snmpE<gt>> block: B<Data> and B<Host>:
-
-=head2 The B<Data> block
-
-The B<Data> block defines a list of values or a table of values that are to be
-queried. The following options can be set:
-
-=over 4
-
-=item B<Type> I<type>
-
-collectd's type that is to be used, e.E<nbsp>g. "if_octets" for interface
-traffic or "users" for a user count. The types are read from the B<TypesDB>
-(see L<collectd.conf(5)>), so you may want to check for which types are
-defined. See L<types.db(5)> for a description of the format of this file.
-
-=item B<Table> I<true|false>
-
-Define if this is a single list of values or a table of values. The difference
-is the following:
-
-When B<Table> is set to B<false>, the OIDs given to B<Values> (see below) are
-queried using the C<GET> SNMP command (see L<snmpget(1)>) and transmitted to
-collectd. B<One> value list is dispatched and, eventually, one file will be
-written.
-
-When B<Table> is set to B<true>, the OIDs given to B<Values> (see below) are
-queried using the C<GETNEXT> SNMP command until the subtree is left. After all
-the lists (think: all columns of the table) have been read B<several> values
-sets will be dispatches and, eventually, several files will be written. If you
-configure a B<Type> (see above) which needs more than one data source (for
-example C<if_octets> which needs C<rx> and C<tx>) you will need to specify more
-than one (two, in the example case) OIDs with the B<Values> option. This has
-nothing to do with the B<Table> setting.
-
-For example, if you want to query the number of users on a system, you can use
-C<HOST-RESOURCES-MIB::hrSystemNumUsers.0>. This is one value and belongs to one
-value list, therefore B<Table> must be set to B<false>. Please note that, in
-this case, you have to include the sequence number (zero in this case) in the
-OID.
-
-Counter example: If you want to query the interface table provided by the
-C<IF-MIB>, e.E<nbsp>g. the bytes transmitted. There are potentially many
-interfaces, so you will want to set B<Table> to B<true>. Because the
-C<if_octets> type needs two values, received and transmitted bytes, you need to
-specify two OIDs in the B<Values> setting, in this case likely
-C<IF-MIB::ifHCInOctets> and C<IF-MIB::ifHCOutOctets>. But, this is because of
-the B<Type> setting, not the B<Table> setting.
-
-Since the semantic of B<Instance> and B<Values> depends on this setting you
-need to set it before setting them. Doing vice verse will result in undefined
-behavior.
-
-=item B<Instance> I<Instance>
-
-Sets the type-instance of the values that are dispatched. The meaning of this
-setting depends on whether B<Table> is set to I<true> or I<false>:
-
-If B<Table> is set to I<true>, I<Instance> is interpreted as an SNMP-prefix
-that will return a list of values. Those values are then used as the actual
-type-instance. An example would be the C<IF-MIB::ifDescr> subtree.
-L<variables(5)> from the SNMP distribution describes the format of OIDs.
-
-If B<Table> is set to I<true> and B<Instance> is omitted, then "SUBID" will be
-used as the instance.
-
-If B<Table> is set to I<false> the actual string configured for I<Instance> is
-copied into the value-list. In this case I<Instance> may be empty, i.E<nbsp>e.
-"".
-
-=item B<InstancePrefix> I<String>
-
-If B<Table> is set to I<true>, you may feel the need to add something to the
-instance of the files. If set, I<String> is prepended to the instance as
-determined by querying the agent. When B<Table> is set to I<false> this option
-has no effect.
-
-The C<UPS-MIB> is an example where you need this setting: It has voltages of
-the inlets, outlets and the battery of an UPS. However, it doesn't provide a
-descriptive column for these voltages. In this case having 1, 2,E<nbsp>... as
-instances is not enough, because the inlet voltages and outlet voltages may
-both have the subids 1, 2,E<nbsp>... You can use this setting to distinguish
-between the different voltages.
-
-=item B<Values> I<OID> [I<OID> ...]
-
-Configures the values to be queried from the SNMP host. The meaning slightly
-changes with the B<Table> setting. L<variables(5)> from the SNMP distribution
-describes the format of OIDs.
-
-If B<Table> is set to I<true>, each I<OID> must be the prefix of all the
-values to query, e.E<nbsp>g. C<IF-MIB::ifInOctets> for all the counters of
-incoming traffic. This subtree is walked (using C<GETNEXT>) until a value from
-outside the subtree is returned.
-
-If B<Table> is set to I<false>, each I<OID> must be the OID of exactly one
-value, e.E<nbsp>g. C<IF-MIB::ifInOctets.3> for the third counter of incoming
-traffic.
-
-=item B<Scale> I<Value>
-
-The gauge-values returned by the SNMP-agent are multiplied by I<Value>.  This
-is useful when values are transferred as a fixed point real number. For example,
-thermometers may transfer B<243> but actually mean B<24.3>, so you can specify
-a scale value of B<0.1> to correct this. The default value is, of course,
-B<1.0>.
-
-This value is not applied to counter-values.
-
-=item B<Shift> I<Value>
-
-I<Value> is added to gauge-values returned by the SNMP-agent after they have
-been multiplied by any B<Scale> value. If, for example, a thermometer returns
-degrees Kelvin you could specify a shift of B<273.15> here to store values in
-degrees Celsius. The default value is, of course, B<0.0>.
-
-This value is not applied to counter-values.
-
-=item B<Ignore> I<Value> [, I<Value> ...]
-
-The ignore values allows to ignore Instances based on their name and the patterns
-specified by the various values you've entered. The match is a glob-type shell
-matching.
-
-=item B<InvertMatch> I<true|false(default)>
-
-The invertmatch value should be use in combination of the Ignore option.
-It changes the behaviour of the Ignore option, from a blacklist behaviour
-when InvertMatch is set to false, to a whitelist when specified to true.
-
-=back
-
-=head2 The Host block
-
-The B<Host> block defines which hosts to query, which SNMP community and
-version to use and which of the defined B<Data> to query.
-
-The argument passed to the B<Host> block is used as the hostname in the data
-stored by collectd.
-
-=over 4
-
-=item B<Address> I<IP-Address>|I<Hostname>
-
-Set the address to connect to.
-
-=item B<Version> B<1>|B<2>|B<3>
-
-Set the SNMP version to use. When giving B<2> version C<2c> is actually used.
-
-=item B<Community> I<Community>
-
-Pass I<Community> to the host. (Ignored for SNMPv3).
-
-=item B<Username> I<Username>
-
-Sets the I<Username> to use for SNMPv3 security.
-
-=item B<SecurityLevel> I<authPriv>|I<authNoPriv>|I<noAuthNoPriv>
-
-Selects the security level for SNMPv3 security.
-
-=item B<Context> I<Context>
-
-Sets the I<Context> for SNMPv3 security.
-
-=item B<AuthProtocol> I<MD5>|I<SHA>
-
-Selects the authentication protocol for SNMPv3 security.
-
-=item B<AuthPassphrase> I<Passphrase>
-
-Sets the authentication passphrase for SNMPv3 security. 
-
-=item B<PrivacyProtocol> I<AES>|I<DES>
-
-Selects the privacy (encryption) protocol for SNMPv3 security.
-
-=item B<PrivacyPassphrase> I<Passphrase>
-
-Sets the privacy (encryption) passphrase for SNMPv3 security. 
-
-=item B<Collect> I<Data> [I<Data> ...]
-
-Defines which values to collect. I<Data> refers to one of the B<Data> block
-above. Since the config file is read top-down you need to define the data
-before using it here.
-
-=item B<Interval> I<Seconds>
-
-Collect data from this host every I<Seconds> seconds. This option is meant for
-devices with not much CPU power, e.E<nbsp>g. network equipment such as
-switches, embedded devices, rack monitoring systems and so on. Since the
-B<Step> of generated RRD files depends on this setting it's wise to select a
-reasonable value once and never change it.
-
-=back
-
-=head1 SEE ALSO
-
-L<collectd(1)>,
-L<collectd.conf(5)>,
-L<snmpget(1)>,
-L<snmpgetnext(1)>,
-L<variables(5)>,
-L<unix(7)>
-
-=head1 AUTHORS
-
-Florian Forster E<lt>octo@collectd.orgE<gt>
-Michael Pilat E<lt>mike@mikepilat.comE<gt>
-
-=cut