Code

collectd.conf(5): sigrok plugin: Improve markup.
authorFlorian Forster <octo@collectd.org>
Wed, 7 Aug 2013 06:14:16 +0000 (08:14 +0200)
committerFlorian Forster <octo@collectd.org>
Wed, 7 Aug 2013 06:14:16 +0000 (08:14 +0200)
src/collectd.conf.pod

index a673a584982842b0985e36ad9f845b5167e92cca..7b9a5598b77c65fae169edc835295c0d2801b15a 100644 (file)
@@ -5148,9 +5148,9 @@ and all other sensors are collected.
 
 =back
 
 
 =back
 
-=head2 Plugin "sigrok"
+=head2 Plugin C<sigrok>
 
 
-The I<sigrok> plugin uses libsigrok to retrieve measurements from any device
+The I<sigrok plugin> uses I<libsigrok> to retrieve measurements from any device
 supported by the L<sigrok|http://sigrok.org/> project.
 
 B<Synopsis>
 supported by the L<sigrok|http://sigrok.org/> project.
 
 B<Synopsis>
@@ -5159,12 +5159,12 @@ B<Synopsis>
    LogLevel 3
    <Device "AC Voltage">
       Driver "fluke-dmm"
    LogLevel 3
    <Device "AC Voltage">
       Driver "fluke-dmm"
-         MinimumInterval 10
-         Conn "/dev/ttyUSB2"
+      MinimumInterval 10
+      Conn "/dev/ttyUSB2"
    </Device>
    <Device "Sound Level">
       Driver "cem-dt-885x"
    </Device>
    <Device "Sound Level">
       Driver "cem-dt-885x"
-         Conn "/dev/ttyUSB1"
+      Conn "/dev/ttyUSB1"
    </Device>
  </Plugin>
 
    </Device>
  </Plugin>
 
@@ -5172,46 +5172,47 @@ B<Synopsis>
 
 =item B<LogLevel> B<0-5>
 
 
 =item B<LogLevel> B<0-5>
 
-The sigrok logging level to pass on to the collectd log, as a number 0-5.
-These levels correspond to None, Errors, Warnings, Informational, Debug
-and Spew, respectively.  The default is 2 (Warnings). The sigrok log messages,
-regardless of their level, are always submitted to collectd at its INFO
-log level.
+The I<sigrok> logging level to pass on to the I<collectd> log, as a number
+between B<0> and B<5> (inclusive). These levels correspond to C<None>,
+C<Errors>, C<Warnings>, C<Informational>, C<Debug >and C<Spew>, respectively.
+The default is B<2> (C<Warnings>). The I<sigrok> log messages, regardless of
+their level, are always submitted to I<collectd> at its INFO log level.
 
 
-=item E<lt>B<Device> I<name>E<gt>
+=item E<lt>B<Device> I<Name>E<gt>
 
 A sigrok-supported device, uniquely identified by this section's options. The
 
 A sigrok-supported device, uniquely identified by this section's options. The
-I<name> is passed to collectd as the I<plugin instance>.
+I<Name> is passed to I<collectd> as the I<plugin instance>.
 
 
-=item B<Driver>
+=item B<Driver> I<DriverName>
 
 The sigrok driver to use for this device.
 
 
 The sigrok driver to use for this device.
 
-=item B<Conn>
+=item B<Conn> I<ConnectionSpec>
 
 If the device cannot be auto-discovered, or more than one might be discovered
 
 If the device cannot be auto-discovered, or more than one might be discovered
-by the driver, I<Conn> specifies the connection string to the device. It can
-be of the form of a serial port (I</dev/ttyUSB2>), or, in case of a non-serial
-USB-connected device, the USB VendorID/ProductID separated by a period
-(I<0403.6001>). A USB device can also be specified as bus.address
-(I<1.41>).
+by the driver, I<ConnectionSpec> specifies the connection string to the device.
+It can be of the form of a device path (e.g.E<nbsp>C</dev/ttyUSB2>), or, in
+case of a non-serial USB-connected device, the USB I<VendorID>B<.>I<ProductID>
+separated by a period (e.g.E<nbsp>C<0403.6001>). A USB device can also be
+specified as I<Bus>B<.>I<Address> (e.g.E<nbsp>C<1.41>).
 
 
-=item B<SerialComm>
+=item B<SerialComm> I<SerialSpec>
 
 For serial devices with non-standard port settings, this option can be used
 
 For serial devices with non-standard port settings, this option can be used
-to specify them in the form I<9600/8n1>. This should not be necessary; drivers
-know how to communicate with devices they support.
+to specify them in a form understood by I<sigrok>, e.g.E<nbsp>C<9600/8n1>.
+This should not be necessary; drivers know how to communicate with devices they
+support.
 
 
-=item B<MinimumInterval>
+=item B<MinimumInterval> I<Seconds>
 
 
-Specifies the minimum time between measurement dispatches to collectd, in
-seconds. Since some sigrok-supported devices can acquire measurements many
+Specifies the minimum time between measurement dispatches to I<collectd>, in
+seconds. Since some I<sigrok> supported devices can acquire measurements many
 times per second, it may be necessary to throttle these. For example, the
 times per second, it may be necessary to throttle these. For example, the
-RRD plugin cannot process writes more than once per second.
+I<RRD plugin> cannot process writes more than once per second.
 
 
-The default MinimumInterval is 0, meaning measurements received from the
-device are always dispatched to collectd. When throttled, unused measurements
-are discarded.
+The default B<MinimumInterval> is B<0>, meaning measurements received from the
+device are always dispatched to I<collectd>. When throttled, unused
+measurements are discarded.
 
 =back
 
 
 =back