Code

Imported upstream version 1.3.0.
[pkg-rrdtool.git] / doc / rrdcreate.1
index 53fc8d98c073cdbf48cd0d603e26bdf77ab3ed10..8809ca0cb9b8a642d52f2e2c8a7753510a259265 100644 (file)
 .\" ========================================================================
 .\"
 .IX Title "RRDCREATE 1"
 .\" ========================================================================
 .\"
 .IX Title "RRDCREATE 1"
-.TH RRDCREATE 1 "2008-05-12" "1.3rc9" "rrdtool"
+.TH RRDCREATE 1 "2008-06-11" "1.3.0" "rrdtool"
 .SH "NAME"
 rrdcreate \- Set up a new Round Robin Database
 .SH "SYNOPSIS"
 .SH "NAME"
 rrdcreate \- Set up a new Round Robin Database
 .SH "SYNOPSIS"
@@ -144,48 +144,47 @@ rrdcreate \- Set up a new Round Robin Database
 The create function of RRDtool lets you set up new Round Robin
 Database (\fB\s-1RRD\s0\fR) files.  The file is created at its final, full size
 and filled with \fI*UNKNOWN*\fR data.
 The create function of RRDtool lets you set up new Round Robin
 Database (\fB\s-1RRD\s0\fR) files.  The file is created at its final, full size
 and filled with \fI*UNKNOWN*\fR data.
-.IP "\fIfilename\fR" 8
-.IX Item "filename"
+.Sh "\fIfilename\fP"
+.IX Subsection "filename"
 The name of the \fB\s-1RRD\s0\fR you want to create. \fB\s-1RRD\s0\fR files should end
 with the extension \fI.rrd\fR. However, \fBRRDtool\fR will accept any
 filename.
 The name of the \fB\s-1RRD\s0\fR you want to create. \fB\s-1RRD\s0\fR files should end
 with the extension \fI.rrd\fR. However, \fBRRDtool\fR will accept any
 filename.
-.IP "\fB\-\-start\fR|\fB\-b\fR \fIstart time\fR (default: now \- 10s)" 8
-.IX Item "--start|-b start time (default: now - 10s)"
+.Sh "\fB\-\-start\fP|\fB\-b\fP \fIstart time\fP (default: now \- 10s)"
+.IX Subsection "--start|-b start time (default: now - 10s)"
 Specifies the time in seconds since 1970\-01\-01 \s-1UTC\s0 when the first
 value should be added to the \fB\s-1RRD\s0\fR. \fBRRDtool\fR will not accept
 any data timed before or at the time specified.
 Specifies the time in seconds since 1970\-01\-01 \s-1UTC\s0 when the first
 value should be added to the \fB\s-1RRD\s0\fR. \fBRRDtool\fR will not accept
 any data timed before or at the time specified.
-.Sp
+.PP
 See also AT-STYLE \s-1TIME\s0 \s-1SPECIFICATION\s0 section in the
 \&\fIrrdfetch\fR documentation for other ways to specify time.
 See also AT-STYLE \s-1TIME\s0 \s-1SPECIFICATION\s0 section in the
 \&\fIrrdfetch\fR documentation for other ways to specify time.
-.IP "\fB\-\-step\fR|\fB\-s\fR \fIstep\fR (default: 300 seconds)" 8
-.IX Item "--step|-s step (default: 300 seconds)"
+.Sh "\fB\-\-step\fP|\fB\-s\fP \fIstep\fP (default: 300 seconds)"
+.IX Subsection "--step|-s step (default: 300 seconds)"
 Specifies the base interval in seconds with which data will be fed
 into the \fB\s-1RRD\s0\fR.
 Specifies the base interval in seconds with which data will be fed
 into the \fB\s-1RRD\s0\fR.
-.IP "\fB\s-1DS:\s0\fR\fIds-name\fR\fB:\fR\fI\s-1DST\s0\fR\fB:\fR\fIdst arguments\fR" 8
-.IX Item "DS:ds-name:DST:dst arguments"
+.Sh "\fB\s-1DS:\s0\fP\fIds-name\fP\fB:\fP\fI\s-1DST\s0\fP\fB:\fP\fIdst arguments\fP"
+.IX Subsection "DS:ds-name:DST:dst arguments"
 A single \fB\s-1RRD\s0\fR can accept input from several data sources (\fB\s-1DS\s0\fR),
 for example incoming and outgoing traffic on a specific communication
 line. With the \fB\s-1DS\s0\fR configuration option you must define some basic
 properties of each data source you want to store in the \fB\s-1RRD\s0\fR.
 A single \fB\s-1RRD\s0\fR can accept input from several data sources (\fB\s-1DS\s0\fR),
 for example incoming and outgoing traffic on a specific communication
 line. With the \fB\s-1DS\s0\fR configuration option you must define some basic
 properties of each data source you want to store in the \fB\s-1RRD\s0\fR.
-.Sp
+.PP
 \&\fIds-name\fR is the name you will use to reference this particular data
 source from an \fB\s-1RRD\s0\fR. A \fIds-name\fR must be 1 to 19 characters long in
 the characters [a\-zA\-Z0\-9_].
 \&\fIds-name\fR is the name you will use to reference this particular data
 source from an \fB\s-1RRD\s0\fR. A \fIds-name\fR must be 1 to 19 characters long in
 the characters [a\-zA\-Z0\-9_].
-.Sp
+.PP
 \&\fI\s-1DST\s0\fR defines the Data Source Type. The remaining arguments of a
 data source entry depend on the data source type. For \s-1GAUGE\s0, \s-1COUNTER\s0,
 \&\s-1DERIVE\s0, and \s-1ABSOLUTE\s0 the format for a data source entry is:
 \&\fI\s-1DST\s0\fR defines the Data Source Type. The remaining arguments of a
 data source entry depend on the data source type. For \s-1GAUGE\s0, \s-1COUNTER\s0,
 \&\s-1DERIVE\s0, and \s-1ABSOLUTE\s0 the format for a data source entry is:
-.Sp
+.PP
 \&\fB\s-1DS:\s0\fR\fIds-name\fR\fB:\fR\fI\s-1GAUGE\s0 | \s-1COUNTER\s0 | \s-1DERIVE\s0 | \s-1ABSOLUTE\s0\fR\fB:\fR\fIheartbeat\fR\fB:\fR\fImin\fR\fB:\fR\fImax\fR
 \&\fB\s-1DS:\s0\fR\fIds-name\fR\fB:\fR\fI\s-1GAUGE\s0 | \s-1COUNTER\s0 | \s-1DERIVE\s0 | \s-1ABSOLUTE\s0\fR\fB:\fR\fIheartbeat\fR\fB:\fR\fImin\fR\fB:\fR\fImax\fR
-.Sp
+.PP
 For \s-1COMPUTE\s0 data sources, the format is:
 For \s-1COMPUTE\s0 data sources, the format is:
-.Sp
+.PP
 \&\fB\s-1DS:\s0\fR\fIds-name\fR\fB:\fR\fI\s-1COMPUTE\s0\fR\fB:\fR\fIrpn-expression\fR
 \&\fB\s-1DS:\s0\fR\fIds-name\fR\fB:\fR\fI\s-1COMPUTE\s0\fR\fB:\fR\fIrpn-expression\fR
-.Sp
+.PP
 In order to decide which data source type to use, review the
 definitions that follow. Also consult the section on \*(L"\s-1HOW\s0 \s-1TO\s0 \s-1MEASURE\s0\*(R"
 for further insight.
 In order to decide which data source type to use, review the
 definitions that follow. Also consult the section on \*(L"\s-1HOW\s0 \s-1TO\s0 \s-1MEASURE\s0\*(R"
 for further insight.
-.RS 8
 .IP "\fB\s-1GAUGE\s0\fR" 4
 .IX Item "GAUGE"
 is for things like temperatures or number of people in a room or the
 .IP "\fB\s-1GAUGE\s0\fR" 4
 .IX Item "GAUGE"
 is for things like temperatures or number of people in a room or the
@@ -207,9 +206,9 @@ example, to measure the rate of people entering or leaving a
 room. Internally, derive works exactly like \s-1COUNTER\s0 but without
 overflow checks. So if your counter does not reset at 32 or 64 bit you
 might want to use \s-1DERIVE\s0 and combine it with a \s-1MIN\s0 value of 0.
 room. Internally, derive works exactly like \s-1COUNTER\s0 but without
 overflow checks. So if your counter does not reset at 32 or 64 bit you
 might want to use \s-1DERIVE\s0 and combine it with a \s-1MIN\s0 value of 0.
-.RS 4
-.IP "\s-1NOTE\s0 on \s-1COUNTER\s0 vs \s-1DERIVE\s0" 4
-.IX Item "NOTE on COUNTER vs DERIVE"
+.Sp
+\&\fB\s-1NOTE\s0 on \s-1COUNTER\s0 vs \s-1DERIVE\s0\fR
+.Sp
 by Don Baarda <don.baarda@baesystems.com>
 .Sp
 If you cannot tolerate ever mistaking the occasional counter reset for a
 by Don Baarda <don.baarda@baesystems.com>
 .Sp
 If you cannot tolerate ever mistaking the occasional counter reset for a
@@ -226,9 +225,6 @@ for high bandwidth interfaces and a 32bit counter, \s-1DERIVE\s0 with min=0 is
 probably preferable. If you are using a 64bit counter, just about any max
 setting will eliminate the possibility of mistaking a reset for a counter
 wrap.
 probably preferable. If you are using a 64bit counter, just about any max
 setting will eliminate the possibility of mistaking a reset for a counter
 wrap.
-.RE
-.RS 4
-.RE
 .IP "\fB\s-1ABSOLUTE\s0\fR" 4
 .IX Item "ABSOLUTE"
 is for counters which get reset upon reading. This is used for fast counters
 .IP "\fB\s-1ABSOLUTE\s0\fR" 4
 .IX Item "ABSOLUTE"
 is for counters which get reset upon reading. This is used for fast counters
@@ -246,24 +242,22 @@ formula. Consolidation functions are then applied normally to the PDPs
 of the \s-1COMPUTE\s0 data source (that is the rpn-expression is only applied
 to generate PDPs). In database software, such data sets are referred
 to as \*(L"virtual\*(R" or \*(L"computed\*(R" columns.
 of the \s-1COMPUTE\s0 data source (that is the rpn-expression is only applied
 to generate PDPs). In database software, such data sets are referred
 to as \*(L"virtual\*(R" or \*(L"computed\*(R" columns.
-.RE
-.RS 8
-.Sp
+.PP
 \&\fIheartbeat\fR defines the maximum number of seconds that may pass
 between two updates of this data source before the value of the
 data source is assumed to be \fI*UNKNOWN*\fR.
 \&\fIheartbeat\fR defines the maximum number of seconds that may pass
 between two updates of this data source before the value of the
 data source is assumed to be \fI*UNKNOWN*\fR.
-.Sp
+.PP
 \&\fImin\fR and \fImax\fR define the expected range values for data supplied by a
 data source. If \fImin\fR and/or \fImax\fR any value outside the defined range
 will be regarded as \fI*UNKNOWN*\fR. If you do not know or care about min and
 max, set them to U for unknown. Note that min and max always refer to the
 processed values of the \s-1DS\s0. For a traffic\-\fB\s-1COUNTER\s0\fR type \s-1DS\s0 this would be
 the maximum and minimum data-rate expected from the device.
 \&\fImin\fR and \fImax\fR define the expected range values for data supplied by a
 data source. If \fImin\fR and/or \fImax\fR any value outside the defined range
 will be regarded as \fI*UNKNOWN*\fR. If you do not know or care about min and
 max, set them to U for unknown. Note that min and max always refer to the
 processed values of the \s-1DS\s0. For a traffic\-\fB\s-1COUNTER\s0\fR type \s-1DS\s0 this would be
 the maximum and minimum data-rate expected from the device.
-.Sp
+.PP
 \&\fIIf information on minimal/maximal expected values is available,
 always set the min and/or max properties. This will help RRDtool in
 doing a simple sanity check on the data supplied when running update.\fR
 \&\fIIf information on minimal/maximal expected values is available,
 always set the min and/or max properties. This will help RRDtool in
 doing a simple sanity check on the data supplied when running update.\fR
-.Sp
+.PP
 \&\fIrpn-expression\fR defines the formula used to compute the PDPs of a
 \&\s-1COMPUTE\s0 data source from other data sources in the same <\s-1RRD\s0>. It is
 similar to defining a \fB\s-1CDEF\s0\fR argument for the graph command. Please
 \&\fIrpn-expression\fR defines the formula used to compute the PDPs of a
 \&\s-1COMPUTE\s0 data source from other data sources in the same <\s-1RRD\s0>. It is
 similar to defining a \fB\s-1CDEF\s0\fR argument for the graph command. Please
@@ -274,22 +268,20 @@ the \s-1RPN\s0 expression, the \s-1COMPUTE\s0 data source may only refer to the
 names of data source listed previously in the create command. This is
 similar to the restriction that \fB\s-1CDEF\s0\fRs must refer only to \fB\s-1DEF\s0\fRs
 and \fB\s-1CDEF\s0\fRs previously defined in the same graph command.
 names of data source listed previously in the create command. This is
 similar to the restriction that \fB\s-1CDEF\s0\fRs must refer only to \fB\s-1DEF\s0\fRs
 and \fB\s-1CDEF\s0\fRs previously defined in the same graph command.
-.RE
-.IP "\fB\s-1RRA:\s0\fR\fI\s-1CF\s0\fR\fB:\fR\fIcf arguments\fR" 8
-.IX Item "RRA:CF:cf arguments"
+.Sh "\fB\s-1RRA:\s0\fP\fI\s-1CF\s0\fP\fB:\fP\fIcf arguments\fP"
+.IX Subsection "RRA:CF:cf arguments"
 The purpose of an \fB\s-1RRD\s0\fR is to store data in the round robin archives
 (\fB\s-1RRA\s0\fR). An archive consists of a number of data values or statistics for
 each of the defined data-sources (\fB\s-1DS\s0\fR) and is defined with an \fB\s-1RRA\s0\fR line.
 The purpose of an \fB\s-1RRD\s0\fR is to store data in the round robin archives
 (\fB\s-1RRA\s0\fR). An archive consists of a number of data values or statistics for
 each of the defined data-sources (\fB\s-1DS\s0\fR) and is defined with an \fB\s-1RRA\s0\fR line.
-.Sp
+.PP
 When data is entered into an \fB\s-1RRD\s0\fR, it is first fit into time slots
 of the length defined with the \fB\-s\fR option, thus becoming a \fIprimary
 data point\fR.
 When data is entered into an \fB\s-1RRD\s0\fR, it is first fit into time slots
 of the length defined with the \fB\-s\fR option, thus becoming a \fIprimary
 data point\fR.
-.Sp
+.PP
 The data is also processed with the consolidation function (\fI\s-1CF\s0\fR) of
 the archive. There are several consolidation functions that
 consolidate primary data points via an aggregate function: \fB\s-1AVERAGE\s0\fR,
 \&\fB\s-1MIN\s0\fR, \fB\s-1MAX\s0\fR, \fB\s-1LAST\s0\fR. 
 The data is also processed with the consolidation function (\fI\s-1CF\s0\fR) of
 the archive. There are several consolidation functions that
 consolidate primary data points via an aggregate function: \fB\s-1AVERAGE\s0\fR,
 \&\fB\s-1MIN\s0\fR, \fB\s-1MAX\s0\fR, \fB\s-1LAST\s0\fR. 
-.RS 8
 .IP "\s-1AVERAGE\s0" 4
 .IX Item "AVERAGE"
 the average of the data points is stored.
 .IP "\s-1AVERAGE\s0" 4
 .IX Item "AVERAGE"
 the average of the data points is stored.
@@ -302,29 +294,27 @@ the largest of the data points is stored.
 .IP "\s-1LAST\s0" 4
 .IX Item "LAST"
 the last data points is used.
 .IP "\s-1LAST\s0" 4
 .IX Item "LAST"
 the last data points is used.
-.RE
-.RS 8
-.Sp
+.PP
 Note that data aggregation inevitably leads to loss of precision and
 information. The trick is to pick the aggregate function such that the
 \&\fIinteresting\fR properties of your data is kept across the aggregation
 process.
 Note that data aggregation inevitably leads to loss of precision and
 information. The trick is to pick the aggregate function such that the
 \&\fIinteresting\fR properties of your data is kept across the aggregation
 process.
-.Sp
+.PP
 The format of \fB\s-1RRA\s0\fR line for these
 consolidation functions is:
 The format of \fB\s-1RRA\s0\fR line for these
 consolidation functions is:
-.Sp
+.PP
 \&\fB\s-1RRA:\s0\fR\fI\s-1AVERAGE\s0 | \s-1MIN\s0 | \s-1MAX\s0 | \s-1LAST\s0\fR\fB:\fR\fIxff\fR\fB:\fR\fIsteps\fR\fB:\fR\fIrows\fR
 \&\fB\s-1RRA:\s0\fR\fI\s-1AVERAGE\s0 | \s-1MIN\s0 | \s-1MAX\s0 | \s-1LAST\s0\fR\fB:\fR\fIxff\fR\fB:\fR\fIsteps\fR\fB:\fR\fIrows\fR
-.Sp
+.PP
 \&\fIxff\fR The xfiles factor defines what part of a consolidation interval may
 be made up from \fI*UNKNOWN*\fR data while the consolidated value is still
 regarded as known. It is given as the ratio of allowed \fI*UNKNOWN*\fR PDPs
 to the number of PDPs in the interval. Thus, it ranges from 0 to 1 (exclusive).
 \&\fIxff\fR The xfiles factor defines what part of a consolidation interval may
 be made up from \fI*UNKNOWN*\fR data while the consolidated value is still
 regarded as known. It is given as the ratio of allowed \fI*UNKNOWN*\fR PDPs
 to the number of PDPs in the interval. Thus, it ranges from 0 to 1 (exclusive).
-.Sp
+.PP
 \&\fIsteps\fR defines how many of these \fIprimary data points\fR are used to build
 a \fIconsolidated data point\fR which then goes into the archive.
 \&\fIsteps\fR defines how many of these \fIprimary data points\fR are used to build
 a \fIconsolidated data point\fR which then goes into the archive.
-.Sp
+.PP
 \&\fIrows\fR defines how many generations of data values are kept in an \fB\s-1RRA\s0\fR.
 \&\fIrows\fR defines how many generations of data values are kept in an \fB\s-1RRA\s0\fR.
-.RE
+Obviously, this has to be greater than zero.
 .SH "Aberrant Behavior Detection with Holt-Winters Forecasting"
 .IX Header "Aberrant Behavior Detection with Holt-Winters Forecasting"
 In addition to the aggregate functions, there are a set of specialized
 .SH "Aberrant Behavior Detection with Holt-Winters Forecasting"
 .IX Header "Aberrant Behavior Detection with Holt-Winters Forecasting"
 In addition to the aggregate functions, there are a set of specialized