threshold plugin: Move the threshold checking code into a plugin.
[collectd.git] / src / collectd.conf.pod
index c1c9a253c31a3ce7d53fdfef28726158735d314e..acdfa927ee61e126d938217fffab383947467334 100644 (file)
@@ -141,7 +141,7 @@ missing when no update has been received for twice the update interval. Since
 this setting uses iterations, the maximum allowed time without update depends
 on the I<Interval> information contained in each value list. This is used in
 the I<Threshold> configuration to dispatch notifications about missing values,
-see L<"THRESHOLD CONFIGURATION"> below.
+see L<collectd-threshold(5)> for details.
 
 =item B<ReadThreads> I<Num>
 
@@ -4530,7 +4530,7 @@ port in numeric form.
 
 =item B<ForceUseProcfs> I<true>|I<false>
 
-By default, the C<thermal> plugin tries to read the statistics from the Linux
+By default, the I<Thermal plugin> tries to read the statistics from the Linux
 C<sysfs> interface. If that is not available, the plugin falls back to the
 C<procfs> interface. By setting this option to I<true>, you can force the
 plugin to use the latter. This option defaults to I<false>.
@@ -4550,9 +4550,18 @@ selection is configured at all, B<all> devices are selected.
 
 =back
 
+=head2 Plugin C<threshold>
+
+The I<Threshold plugin> checks values collected or received by I<collectd>
+against a configurable I<threshold> and issues I<notifications> if values are
+out of bounds.
+
+Documentation for this plugin is available in the L<collectd-threshold(5)>
+manual page.
+
 =head2 Plugin C<tokyotyrant>
 
-The C<tokyotyrant plugin> connects to a TokyoTyrant server and collects a
+The I<TokyoTyrant plugin> connects to a TokyoTyrant server and collects a
 couple metrics: number of records, and database size on disk.
 
 =over 4
@@ -4799,170 +4808,6 @@ number.
 
 =back
 
-=head1 THRESHOLD CONFIGURATION
-
-Starting with version C<4.3.0> collectd has support for B<monitoring>. By that
-we mean that the values are not only stored or sent somewhere, but that they
-are judged and, if a problem is recognized, acted upon. The only action
-collectd takes itself is to generate and dispatch a "notification". Plugins can
-register to receive notifications and perform appropriate further actions.
-
-Since systems and what you expect them to do differ a lot, you can configure
-B<thresholds> for your values freely. This gives you a lot of flexibility but
-also a lot of responsibility.
-
-Every time a value is out of range a notification is dispatched. This means
-that the idle percentage of your CPU needs to be less then the configured
-threshold only once for a notification to be generated. There's no such thing
-as a moving average or similar - at least not now.
-
-Also, all values that match a threshold are considered to be relevant or
-"interesting". As a consequence collectd will issue a notification if they are
-not received for B<Timeout> iterations. The B<Timeout> configuration option is
-explained in section L<"GLOBAL OPTIONS">. If, for example, B<Timeout> is set to
-"2" (the default) and some hosts sends it's CPU statistics to the server every
-60 seconds, a notification will be dispatched after about 120 seconds. It may
-take a little longer because the timeout is checked only once each B<Interval>
-on the server.
-
-When a value comes within range again or is received after it was missing, an
-"OKAY-notification" is dispatched.
-
-Here is a configuration example to get you started. Read below for more
-information.
-
- <Threshold>
-   <Type "foo">
-     WarningMin    0.00
-     WarningMax 1000.00
-     FailureMin    0.00
-     FailureMax 1200.00
-     Invert false
-     Instance "bar"
-   </Type>
-
-   <Plugin "interface">
-     Instance "eth0"
-     <Type "if_octets">
-       FailureMax 10000000
-       DataSource "rx"
-     </Type>
-   </Plugin>
-
-   <Host "hostname">
-     <Type "cpu">
-       Instance "idle"
-       FailureMin 10
-     </Type>
-
-     <Plugin "memory">
-       <Type "memory">
-         Instance "cached"
-         WarningMin 100000000
-       </Type>
-     </Plugin>
-
-     <Type "load">
-       DataSource "midterm"
-       FailureMax 4
-       Hits 3
-       Hysteresis 3
-     </Type>
-   </Host>
- </Threshold>
-
-There are basically two types of configuration statements: The C<Host>,
-C<Plugin>, and C<Type> blocks select the value for which a threshold should be
-configured. The C<Plugin> and C<Type> blocks may be specified further using the
-C<Instance> option. You can combine the block by nesting the blocks, though
-they must be nested in the above order, i.E<nbsp>e. C<Host> may contain either
-C<Plugin> and C<Type> blocks, C<Plugin> may only contain C<Type> blocks and
-C<Type> may not contain other blocks. If multiple blocks apply to the same
-value the most specific block is used.
-
-The other statements specify the threshold to configure. They B<must> be
-included in a C<Type> block. Currently the following statements are recognized:
-
-=over 4
-
-=item B<FailureMax> I<Value>
-
-=item B<WarningMax> I<Value>
-
-Sets the upper bound of acceptable values. If unset defaults to positive
-infinity. If a value is greater than B<FailureMax> a B<FAILURE> notification
-will be created. If the value is greater than B<WarningMax> but less than (or
-equal to) B<FailureMax> a B<WARNING> notification will be created.
-
-=item B<FailureMin> I<Value>
-
-=item B<WarningMin> I<Value>
-
-Sets the lower bound of acceptable values. If unset defaults to negative
-infinity. If a value is less than B<FailureMin> a B<FAILURE> notification will
-be created. If the value is less than B<WarningMin> but greater than (or equal
-to) B<FailureMin> a B<WARNING> notification will be created.
-
-=item B<DataSource> I<DSName>
-
-Some data sets have more than one "data source". Interesting examples are the
-C<if_octets> data set, which has received (C<rx>) and sent (C<tx>) bytes and
-the C<disk_ops> data set, which holds C<read> and C<write> operations. The
-system load data set, C<load>, even has three data sources: C<shortterm>,
-C<midterm>, and C<longterm>.
-
-Normally, all data sources are checked against a configured threshold. If this
-is undesirable, or if you want to specify different limits for each data
-source, you can use the B<DataSource> option to have a threshold apply only to
-one data source.
-
-=item B<Invert> B<true>|B<false>
-
-If set to B<true> the range of acceptable values is inverted, i.E<nbsp>e.
-values between B<FailureMin> and B<FailureMax> (B<WarningMin> and
-B<WarningMax>) are not okay. Defaults to B<false>.
-
-=item B<Persist> B<true>|B<false>
-
-Sets how often notifications are generated. If set to B<true> one notification
-will be generated for each value that is out of the acceptable range. If set to
-B<false> (the default) then a notification is only generated if a value is out
-of range but the previous value was okay.
-
-This applies to missing values, too: If set to B<true> a notification about a
-missing value is generated once every B<Interval> seconds. If set to B<false>
-only one such notification is generated until the value appears again.
-
-=item B<Percentage> B<true>|B<false>
-
-If set to B<true>, the minimum and maximum values given are interpreted as
-percentage value, relative to the other data sources. This is helpful for
-example for the "df" type, where you may want to issue a warning when less than
-5E<nbsp>% of the total space is available. Defaults to B<false>.
-
-=item B<Hits> I<Value>
-
-Sets the number of occurrences which the threshold must be arised before to
-dispatch any notification or, in other words, the number of B<Interval>s
-than the threshold must be match before dispatch any notification.
-
-=item B<Hysteresis> I<Value>
-
-Sets the hysteresis value for threshold. The hysteresis is a method to
-prevent flapping between states, until a new received value for
-a previously matched threshold down below the threshold condition
-(B<WarningMax>, B<FailureMin> or everthing else) minus the hysteresis value,
-the failure (respectively warning) state will be keep.
-
-=item B<Interesting> B<true>|B<false>
-
-If set to B<true> (the default), the threshold must be treated as
-interesting and, when a number of B<Timeout> values will lost, then
-a missing notification will be dispatched. On the other hand, if set to
-B<false>, the missing notification will never dispatched for this threshold.
-
-=back
-
 =head1 FILTER CONFIGURATION
 
 Starting with collectd 4.6 there is a powerful filtering infrastructure