summary | shortlog | log | commit | commitdiff | tree
raw | patch | inline | side by side (parent: 11425be)
raw | patch | inline | side by side (parent: 11425be)
author | Ruben Kerkhof <ruben@rubenkerkhof.com> | |
Sun, 13 Dec 2015 12:07:05 +0000 (13:07 +0100) | ||
committer | Florian Forster <octo@collectd.org> | |
Thu, 17 Dec 2015 09:27:20 +0000 (10:27 +0100) |
Signed-off-by: Florian Forster <octo@collectd.org>
src/barometer.c | patch | blob | history |
diff --git a/src/barometer.c b/src/barometer.c
index a6d98354d7ae2857c9be395e0bb81254c3c2d7cb..84ffdfcb0db74113b8bd18a4ae611df11c858834 100644 (file)
--- a/src/barometer.c
+++ b/src/barometer.c
/* ------------ MPL115 defines ------------ */
/* I2C address of the MPL115 sensor */
#define MPL115_I2C_ADDRESS 0x60
-
-/* register addresses */
+
+/* register addresses */
#define MPL115_ADDR_CONV 0x00
#define MPL115_ADDR_COEFFS 0x04
-
-/* register sizes */
+
+/* register sizes */
#define MPL115_NUM_CONV 4
#define MPL115_NUM_COEFFS 12
-
-/* commands / addresses */
+
+/* commands / addresses */
#define MPL115_CMD_CONVERT_PRESS 0x10
#define MPL115_CMD_CONVERT_TEMP 0x11
#define MPL115_CMD_CONVERT_BOTH 0x12
-
+
#define MPL115_CONVERSION_RETRIES 5
#define MPL3115_PT_DATA_DREM 0x04
#define MPL3115_PT_DATA_PDEF 0x02
#define MPL3115_PT_DATA_TDEF 0x01
-
+
#define MPL3115_DR_STATUS_TDR 0x02
#define MPL3115_DR_STATUS_PDR 0x04
#define MPL3115_DR_STATUS_PTDR 0x08
#define MPL3115_DR_STATUS_DR (MPL3115_DR_STATUS_TDR | MPL3115_DR_STATUS_PDR | MPL3115_DR_STATUS_PTDR)
-
+
#define MPL3115_DR_STATUS_TOW 0x20
#define MPL3115_DR_STATUS_POW 0x40
#define MPL3115_DR_STATUS_PTOW 0x80
/* I2C address of the BMP085 sensor */
#define BMP085_I2C_ADDRESS 0x77
-/* register addresses */
+/* register addresses */
#define BMP085_ADDR_ID_REG 0xD0
#define BMP085_ADDR_VERSION 0xD1
#define BMP085_ADDR_CTRL_REG 0xF4
#define BMP085_ADDR_COEFFS 0xAA
-/* register sizes */
+/* register sizes */
#define BMP085_NUM_COEFFS 22
/* commands, values */
};
static int config_keys_num = STATIC_ARRAY_SIZE(config_keys);
-
+
static char * config_device = NULL; /**< I2C bus device */
static int config_oversample = 1; /**< averaging window */
static double config_altitude = NAN; /**< altitude */
static int config_normalize = 0; /**< normalization method */
-
+
static _Bool configured = 0; /**< the whole plugin config status */
-
+
static int i2c_bus_fd = -1; /**< I2C bus device FD */
static enum Sensor_type sensor_type = Sensor_none; /**< detected/used sensor type */
static averaging_t temperature_averaging = { NULL, 0, 0L, 0 };
-/**
+/**
* Create / allocate averaging buffer
*
* The buffer is initialized with zeros.
avg->ring_buffer[avg->ring_buffer_head] = sample;
avg->ring_buffer_head = (avg->ring_buffer_head+1) % avg->ring_buffer_size;
result = (double)(avg->ring_buffer_sum) / (double)(avg->ring_buffer_size);
-
- DEBUG ("barometer: averaging_add_sample - added %ld, result = %lf",
- sample,
+
+ DEBUG ("barometer: averaging_add_sample - added %ld, result = %lf",
+ sample,
result);
return result;
list = list->next;
continue;
}
-
+
for(i=0; i<REF_TEMP_AVG_NUM*list->num_values; ++i)
{
DEBUG ("barometer: get_reference_temperature - history %d: %lf",
}
list = list->next;
} /* while sensor list */
-
+
if(*result == NAN)
{
ERROR("barometer: get_reference_temperature - no sensor available (yet?)");
/* ------------------------ MPL115 access ------------------------ */
-/**
+/**
* Detect presence of a MPL115 pressure sensor.
*
* Unfortunately there seems to be no ID register so we just try to read first
* MPL115. We should use this check as the last resort (which would be the typical
* case anyway since MPL115 is the least accurate sensor).
* As a sideeffect will leave set I2C slave address.
- *
+ *
* @return 1 if MPL115, 0 otherwise
*/
static int MPL115_detect(void)
Pcomp = mpl115_coeffA0 + \
(mpl115_coeffB1 + mpl115_coeffC11*adc_pressure + mpl115_coeffC12*adc_temp) * adc_pressure + \
(mpl115_coeffB2 + mpl115_coeffC22*adc_temp) * adc_temp;
-
+
*pressure = ((1150.0-500.0) * Pcomp / 1023.0) + 500.0;
*temperature = (472.0 - adc_temp) / 5.35 + 25.0;
DEBUG ("barometer: MPL115_convert_adc_to_real - got %lf hPa, %lf C",
/* ------------------------ MPL3115 access ------------------------ */
-/**
+/**
* Detect presence of a MPL3115 pressure sensor by checking register "WHO AM I"
*
* As a sideeffect will leave set I2C slave address.
- *
+ *
* @return 1 if MPL3115, 0 otherwise
*/
static int MPL3115_detect(void)
return 0;
}
-/**
+/**
* Adjusts oversampling to values supported by MPL3115
*
- * MPL3115 supports only power of 2 in the range 1 to 128.
+ * MPL3115 supports only power of 2 in the range 1 to 128.
*/
static void MPL3115_adjust_oversampling(void)
{
}
DEBUG("barometer: MPL3115_adjust_oversampling - correcting oversampling from %d to %d",
- config_oversample,
+ config_oversample,
new_val);
config_oversample = new_val;
}
-/**
- * Read sensor averegaed measurements
+/**
+ * Read sensor averaged measurements
*
* @param pressure averaged measured pressure
* @param temperature averaged measured temperature
__u8 data[MPL3115_NUM_CONV_VALS];
long int tmp_value = 0;
char errbuf[1024];
-
+
/* Set Active - activate the device from standby */
res = i2c_smbus_read_byte_data(i2c_bus_fd, MPL3115_REG_CTRL_REG1);
if (res < 0)
return 1;
}
ctrl = res;
- res = i2c_smbus_write_byte_data(i2c_bus_fd,
- MPL3115_REG_CTRL_REG1,
+ res = i2c_smbus_write_byte_data(i2c_bus_fd,
+ MPL3115_REG_CTRL_REG1,
ctrl | MPL3115_CTRL_REG1_SBYB);
if (res < 0)
{
sstrerror (errno, errbuf, sizeof (errbuf)));
return 1;
}
-
+
/* base sleep is 5ms x OST */
usleep(5000 * config_oversample);
-
+
/* check the flags/status if ready */
res = i2c_smbus_read_byte_data(i2c_bus_fd, MPL3115_REG_STATUS);
if (res < 0)
sstrerror (errno, errbuf, sizeof (errbuf)));
return 1;
}
-
+
while ((res & MPL3115_DR_STATUS_DR) != MPL3115_DR_STATUS_DR)
{
/* try some extra sleep... */
usleep(10000);
-
+
/* ... and repeat the check. The conversion has to finish sooner or later. */
res = i2c_smbus_read_byte_data(i2c_bus_fd, MPL3115_REG_STATUS);
if (res < 0)
return 1;
}
}
-
+
/* Now read all the data in one block. There is address autoincrement. */
- res = i2c_smbus_read_i2c_block_data(i2c_bus_fd,
- MPL3115_REG_OUT_P_MSB,
+ res = i2c_smbus_read_i2c_block_data(i2c_bus_fd,
+ MPL3115_REG_OUT_P_MSB,
MPL3115_NUM_CONV_VALS,
data);
if (res < 0)
sstrerror (errno, errbuf, sizeof (errbuf)));
return 1;
}
-
+
tmp_value = (data[0] << 16) | (data[1] << 8) | data[2];
*pressure = ((double) tmp_value) / 4.0 / 16.0 / 100.0;
DEBUG ("barometer: MPL3115_read - absolute pressure = %lf hPa", *pressure);
-
+
if(data[3] > 0x7F)
{
data[3] = ~data[3] + 1;
{
*temperature = data[3];
}
-
+
*temperature += (double)(data[4]) / 256.0;
DEBUG ("barometer: MPL3115_read - temperature = %lf C", *temperature);
-
+
return 0;
}
-/**
+/**
* Initialize MPL3115 for barometeric measurements
- *
+ *
* @return 0 if successful
*/
static int MPL3115_init_sensor(void)
__s32 res;
__s8 offset;
char errbuf[1024];
-
+
/* Reset the sensor. It will reset immediately without ACKing */
/* the transaction, so no error handling here. */
- i2c_smbus_write_byte_data(i2c_bus_fd,
- MPL3115_REG_CTRL_REG1,
+ i2c_smbus_write_byte_data(i2c_bus_fd,
+ MPL3115_REG_CTRL_REG1,
MPL3115_CTRL_REG1_RST);
-
+
/* wait some time for the reset to finish */
usleep(100000);
/* now it should be in standby already so we can go and configure it */
-
+
/* Set temperature offset. */
/* result = ADCtemp + offset [C] */
offset = (__s8) (config_temp_offset * 16.0);
sstrerror (errno, errbuf, sizeof (errbuf)));
return -1;
}
-
+
/* Set pressure offset. */
/* result = ADCpress + offset [hPa] */
offset = (__s8) (config_press_offset * 100.0 / 4.0);
}
/* Enable Data Flags in PT_DATA_CFG - flags on both pressure and temp */
- res = i2c_smbus_write_byte_data(i2c_bus_fd,
+ res = i2c_smbus_write_byte_data(i2c_bus_fd,
MPL3115_REG_PT_DATA_CFG,
MPL3115_PT_DATA_DREM \
| MPL3115_PT_DATA_PDEF \
return -1;
}
- /* Set to barometer with an OSR */
- res = i2c_smbus_write_byte_data(i2c_bus_fd,
- MPL3115_REG_CTRL_REG1,
+ /* Set to barometer with an OSR */
+ res = i2c_smbus_write_byte_data(i2c_bus_fd,
+ MPL3115_REG_CTRL_REG1,
mpl3115_oversample);
if (res < 0)
{
/* ------------------------ BMP085 access ------------------------ */
-/**
+/**
* Detect presence of a BMP085 pressure sensor by checking its ID register
*
* As a sideeffect will leave set I2C slave address.
- *
+ *
* @return 1 if BMP085, 0 otherwise
*/
static int BMP085_detect(void)
}
-/**
+/**
* Adjusts oversampling settings to values supported by BMP085
*
- * BMP085 supports only 1,2,4 or 8 samples.
+ * BMP085 supports only 1,2,4 or 8 samples.
*/
static void BMP085_adjust_oversampling(void)
{
}
DEBUG("barometer: BMP085_adjust_oversampling - correcting oversampling from %d to %d",
- config_oversample,
+ config_oversample,
new_val);
config_oversample = new_val;
}
-/**
+/**
* Read the BMP085 sensor conversion coefficients.
*
* These are (device specific) constants so we can read them just once.
static int BMP085_read_coeffs(void)
{
__s32 res;
- __u8 coeffs[BMP085_NUM_COEFFS];
+ __u8 coeffs[BMP085_NUM_COEFFS];
char errbuf[1024];
- res = i2c_smbus_read_i2c_block_data(i2c_bus_fd,
+ res = i2c_smbus_read_i2c_block_data(i2c_bus_fd,
BMP085_ADDR_COEFFS,
- BMP085_NUM_COEFFS,
+ BMP085_NUM_COEFFS,
coeffs);
if (res < 0)
{
sstrerror (errno, errbuf, sizeof (errbuf)));
return -1;
}
-
+
bmp085_AC1 = ((int16_t) coeffs[0] <<8) | (int16_t) coeffs[1];
bmp085_AC2 = ((int16_t) coeffs[2] <<8) | (int16_t) coeffs[3];
bmp085_AC3 = ((int16_t) coeffs[4] <<8) | (int16_t) coeffs[5];
X2 = (((long)bmp085_AC2 * B6) >> 11);
X3 = X1 + X2;
B3 = (((((long)bmp085_AC1 * 4) + X3) << bmp085_oversampling) + 2) >> 2;
-
+
/* B4 */
X1 = (((long)bmp085_AC3*B6) >> 13);
X2 = (bmp085_B1*((B6*B6) >> 12) ) >> 16;
X3 = ((X1 + X2) + 2 ) >> 2;
B4 = ((long)bmp085_AC4* (unsigned long)(X3 + 32768)) >> 15;
-
+
/* B7, P */
B7 = (unsigned long)(adc_pressure - B3)*(50000>>bmp085_oversampling);
if( B7 < 0x80000000 )
X1 = (X1 * 3038) >> 16;
X2 = ((-7357) * P) >> 16;
P = P + ( ( X1 + X2 + 3791 ) >> 4);
-
- *pressure = P / 100.0; // in [hPa]
+
+ *pressure = P / 100.0; // in [hPa]
DEBUG ("barometer: BMP085_convert_adc_to_real - got %lf hPa, %lf C",
*pressure,
*temperature);
}
-
-/**
+
+/**
* Read compensated sensor measurements
*
* @param pressure averaged measured pressure
usleep(BMP085_TIME_CNV_TEMP); /* wait for the conversion */
res = i2c_smbus_read_i2c_block_data( i2c_bus_fd,
- BMP085_ADDR_CONV,
+ BMP085_ADDR_CONV,
2,
- measBuff);
+ measBuff);
if (res < 0)
{
ERROR ("barometer: BMP085_read - problem reading temperature data: %s",
return 1;
}
- adc_temperature = ( (unsigned short)measBuff[0] << 8 ) + measBuff[1];
-
+ adc_temperature = ( (unsigned short)measBuff[0] << 8 ) + measBuff[1];
+
/* get presure */
res = i2c_smbus_write_byte_data( i2c_bus_fd,
- BMP085_ADDR_CTRL_REG,
+ BMP085_ADDR_CTRL_REG,
bmp085_cmdCnvPress );
if (res < 0)
{
usleep(bmp085_timeCnvPress); /* wait for the conversion */
res = i2c_smbus_read_i2c_block_data( i2c_bus_fd,
- BMP085_ADDR_CONV,
+ BMP085_ADDR_CONV,
3,
measBuff );
if (res < 0)
}
adc_pressure = (long)((((ulong)measBuff[0]<<16) | ((ulong)measBuff[1]<<8) | (ulong)measBuff[2] ) >> (8 - bmp085_oversampling));
-
+
DEBUG ("barometer: BMP085_read - raw pressure ADC value = %ld, " \
"raw temperature ADC value = %ld",
/* ------------------------ Sensor detection ------------------------ */
-/**
+/**
* Detect presence of a supported sensor.
*
* As a sideeffect will leave set I2C slave address.
* The detection is done in the order BMP085, MPL3115, MPL115 and stops after
* first sensor beeing found.
- *
+ *
* @return detected sensor type
*/
enum Sensor_type Detect_sensor_type(void)
* - MSLP_INTERNATIONAL - see http://en.wikipedia.org/wiki/Atmospheric_pressure#Altitude_atmospheric_pressure_variation
* Requires #config_altitude
*
- * - MSLP_DEU_WETT - formula as recommended by the Deutsche Wetterdienst. See
+ * - MSLP_DEU_WETT - formula as recommended by the Deutsche Wetterdienst. See
* http://de.wikipedia.org/wiki/Barometrische_H%C3%B6henformel#Theorie
* Requires both #config_altitude and temperature reference(s).
*
case MSLP_NONE:
mean = abs_pressure;
break;
-
+
case MSLP_INTERNATIONAL:
mean = abs_pressure / \
pow(1.0 - 0.0065*config_altitude/288.15, 9.80665*0.0289644/(8.31447*0.0065));
break;
-
+
case MSLP_DEU_WETT:
{
double E; /* humidity */
break;
default:
- ERROR ("barometer: abs_to_mean_sea_level_pressure: wrong conversion method %d",
+ ERROR ("barometer: abs_to_mean_sea_level_pressure: wrong conversion method %d",
config_normalize);
mean = abs_pressure;
break;
config_normalize,
mean);
- return mean;
+ return mean;
}
/* ------------------------ main plugin callbacks ------------------------ */
-/**
+/**
* Main plugin configuration callback (using simple config)
- *
+ *
* @param key configuration key we should process
* @param value configuration value we should process
- *
+ *
* @return Zero when successful.
*/
static int collectd_barometer_config (const char *key, const char *value)
{
config_temp_offset = atof(value);
}
- else
+ else
{
return -1;
}
}
-/**
+/**
* Shutdown callback.
- *
+ *
* Close I2C and delete all the buffers.
- *
+ *
* @return Zero when successful (at the moment the only possible outcome)
*/
static int collectd_barometer_shutdown(void)
}
-/**
+/**
* Plugin read callback for MPL115.
- *
+ *
* Dispatching will create values:
* - <hostname>/barometer-mpl115/pressure-normalized
* - <hostname>/barometer-mpl115/pressure-absolute
value_list_t vl = VALUE_LIST_INIT;
value_t values[1];
-
+
DEBUG("barometer: MPL115_collectd_barometer_read");
if (!configured)
}
-/**
+/**
* Plugin read callback for MPL3115.
- *
+ *
* Dispatching will create values:
* - <hostname>/barometer-mpl3115/pressure-normalized
* - <hostname>/barometer-mpl3115/pressure-absolute
static int MPL3115_collectd_barometer_read (void)
{
int result = 0;
-
+
double pressure = 0.0;
double temperature = 0.0;
double norm_pressure = 0.0;
-
+
value_list_t vl = VALUE_LIST_INIT;
value_t values[1];
-
+
DEBUG("barometer: MPL3115_collectd_barometer_read");
-
+
if (!configured)
{
return -1;
}
-
+
result = MPL3115_read(&pressure, &temperature);
if(result)
return result;
}
-/**
+/**
* Plugin read callback for BMP085.
- *
+ *
* Dispatching will create values:
* - <hostname>/barometer-bmp085/pressure-normalized
* - <hostname>/barometer-bmp085/pressure-absolute
static int BMP085_collectd_barometer_read (void)
{
int result = 0;
-
+
double pressure = 0.0;
double temperature = 0.0;
double norm_pressure = 0.0;
-
+
value_list_t vl = VALUE_LIST_INIT;
value_t values[1];
-
+
DEBUG("barometer: BMP085_collectd_barometer_read");
-
+
if (!configured)
{
return -1;
}
-
+
result = BMP085_read(&pressure, &temperature);
if(result)
return result;
}
-/**
+/**
* Initialization callback
- *
+ *
* Check config, initialize I2C bus access, conversion coefficients and averaging
* ring buffers
- *
+ *
* @return Zero when successful.
*/
static int collectd_barometer_init (void)
case Sensor_MPL3115:
{
MPL3115_adjust_oversampling();
-
+
if(MPL3115_init_sensor())
return -1;
-
+
plugin_register_read ("barometer", MPL3115_collectd_barometer_read);
}
break;
ERROR("barometer: collectd_barometer_init pressure averaging init failed");
return -1;
}
-
+
if (averaging_create (&temperature_averaging, config_oversample))
{
ERROR("barometer: collectd_barometer_init temperature averaging init failed");
return -1;
}
-
+
if (MPL115_read_coeffs() < 0)
return -1;
-
+
plugin_register_read ("barometer", MPL115_collectd_barometer_read);
}
break;
ERROR("barometer: collectd_barometer_init - no supported sensor found");
return -1;
}
-
+
configured = 1;
return 0;
/* ------------------------ plugin register / entry point ------------------------ */
-/**
+/**
* Plugin "entry" - register all callback.
- *
+ *
*/
void module_register (void)
{
- plugin_register_config ("barometer",
- collectd_barometer_config,
- config_keys,
+ plugin_register_config ("barometer",
+ collectd_barometer_config,
+ config_keys,
config_keys_num);
plugin_register_init ("barometer", collectd_barometer_init);