netapp plugin: Set the HAVE_VOLUME_USAGE_SIS_SAVED after determining the value.
authorFlorian Forster <octo@leeloo.lan.home.verplant.org>
Tue, 29 Sep 2009 13:53:12 +0000 (15:53 +0200)
committerFlorian Forster <octo@leeloo.lan.home.verplant.org>
Tue, 29 Sep 2009 13:53:12 +0000 (15:53 +0200)
src/netapp.c

index 57fb59de5c5ef0be861729bcc24c400ca0d818ed..1e0834b8175042464b417a27b75f751225eba9a8 100644 (file)
@@ -1293,6 +1293,7 @@ static int cna_handle_volume_usage_data (const char *hostname, /* {{{ */
                if ((sis_saved_reported >> 32) != 0) {
                        /* In case they ever fix this bug. */
                        v->sis_saved = sis_saved_reported;
+                       v->flags |= HAVE_VOLUME_USAGE_SIS_SAVED;
                } else { /* really hacky work-around code. {{{ */
                        uint64_t sis_saved_percent;
                        uint64_t sis_saved_guess;
@@ -1336,6 +1337,7 @@ static int cna_handle_volume_usage_data (const char *hostname, /* {{{ */
                                else
                                        v->sis_saved = guess3;
                        }
+                       v->flags |= HAVE_VOLUME_USAGE_SIS_SAVED;
                } /* }}} end of 32-bit workaround */