diff --git a/src/collectd.pod b/src/collectd.pod
index f5ed782c07693d2eb60f6dfb777e354737f13f64..8ee77ea26a8fec042a49d33eed80e0e99bf14f3b 100644 (file)
--- a/src/collectd.pod
+++ b/src/collectd.pod
=item
+Motherboard monitor (I<mbmon>)
+
+=item
+
Memory usage (I<memory>)
=item
e:<type>:<size>
+If C<size> is less than or equal to zero, C<size> is ignored.
+
Spam score:
s:<value>
The B<lm_sensors> homepage can be found at
L<http://secure.netroedge.com/~lm78/>.
+=head2 mbmon
+
+The B<mbmon> module uses mbmon to retrieve temperature, voltage, etc.
+
+collectd connects to B<localhost> (127.0.0.1), port B<411/tcp>.
+The B<Host> and B<Port> options can be used to change these
+default values. See L<collectd.conf(5)> for details. C<mbmon> has to be
+running to work correctly. If C<mbmon> is not running timeouts may appear
+which may interfere with other statistics..
+
+C<mbmon> must be run with the -r option ("print TAG and Value format");
+Debian's /etc/init.d/mbmon script already does this, other people
+will need to ensure that this is the case.
+
=head2 hddtemp
To get values from B<hddtemp> collectd connects to B<localhost> (127.0.0.1),
=head1 SEE ALSO
L<collectd.conf(5)>, L<rrdtool(1)>, L<sensors(1)>, L<hddtemp(8)>,
+L<mbmon(1)>,
L<kstat(3KSTAT)>
=head1 AUTHOR