diff --git a/src/collectd.conf.in b/src/collectd.conf.in
index ecc45c9ab9bd9320db6b68fa8a8fb9b63042566a..4a88e6646f7dec844ea208231e6867676c4d2e60 100644 (file)
--- a/src/collectd.conf.in
+++ b/src/collectd.conf.in
#PluginDir "@libdir@/@PACKAGE_NAME@"
#TypesDB "@prefix@/share/@PACKAGE_NAME@/types.db"
+#----------------------------------------------------------------------------#
+# When enabled, plugins are loaded automatically with the default options #
+# when an appropriate <Plugin ...> block is encountered. #
+# Disabled by default. #
+#----------------------------------------------------------------------------#
+#AutoLoadPlugin false
+
#----------------------------------------------------------------------------#
# Interval at which to query values. This may be overwritten on a per-plugin #
# base by using the 'Interval' option of the LoadPlugin block: #
#@BUILD_PLUGIN_BIND_TRUE@LoadPlugin bind
#@BUILD_PLUGIN_CONNTRACK_TRUE@LoadPlugin conntrack
#@BUILD_PLUGIN_CONTEXTSWITCH_TRUE@LoadPlugin contextswitch
+#@BUILD_PLUGIN_CGROUPS_TRUE@LoadPlugin cgroups
@BUILD_PLUGIN_CPU_TRUE@@BUILD_PLUGIN_CPU_TRUE@LoadPlugin cpu
#@BUILD_PLUGIN_CPUFREQ_TRUE@LoadPlugin cpufreq
@LOAD_PLUGIN_CSV@LoadPlugin csv
#@BUILD_PLUGIN_LIBVIRT_TRUE@LoadPlugin libvirt
@BUILD_PLUGIN_LOAD_TRUE@@BUILD_PLUGIN_LOAD_TRUE@LoadPlugin load
#@BUILD_PLUGIN_LPAR_TRUE@LoadPlugin lpar
+#@BUILD_PLUGIN_LVM_TRUE@LoadPlugin lvm
#@BUILD_PLUGIN_MADWIFI_TRUE@LoadPlugin madwifi
#@BUILD_PLUGIN_MBMON_TRUE@LoadPlugin mbmon
#@BUILD_PLUGIN_MD_TRUE@LoadPlugin md
#@BUILD_PLUGIN_USERS_TRUE@LoadPlugin users
#@BUILD_PLUGIN_UUID_TRUE@LoadPlugin uuid
#@BUILD_PLUGIN_VARNISH_TRUE@LoadPlugin varnish
+#@BUILD_PLUGIN_MIC_TRUE@LoadPlugin mic
#@BUILD_PLUGIN_VMEM_TRUE@LoadPlugin vmem
#@BUILD_PLUGIN_VSERVER_TRUE@LoadPlugin vserver
-#@BUILD_PLUGIN_VOLUME_TRUE@LoadPlugin volume
#@BUILD_PLUGIN_WIRELESS_TRUE@LoadPlugin wireless
#@BUILD_PLUGIN_WRITE_GRAPHITE_TRUE@LoadPlugin write_graphite
#@BUILD_PLUGIN_WRITE_HTTP_TRUE@LoadPlugin write_http
# UUIDFile "/etc/uuid"
#</Plugin>
+#<Plugin mic>
+# ShowCPU true
+# ShowCPUCores true
+# ShowMemory true
+# ShowTemperatures true
+## Temperature Sensors can be ignored/shown by repeated #Temperature lines, and
+## then inverted with a IgnoreSelectedTemperature.
+## Known Temperature sensors: die, devmem, fin, fout, vccp, vddg, vddq
+# Temperature vddg
+# IgnoreSelectedTemperature true
+# ShowPower true
+## Power Sensors can be ignored/shown by repeated #Power lines, and
+## then inverted with a IgnoreSelectedTemperature.
+## Known Temperature sensors: total0, total1, inst, imax, pci3, c2x3, c2x4, vccp, vddg, vddq
+# Power total1
+# IgnoreSelectedPower true
+#</Plugin>
+
#<Plugin varnish>
# This tag support an argument if you want to
# monitor the local instance just use </Instance>
# <Instance>
# CollectCache true
# CollectBackend true
+# CollectBan false # Varnish 3 only
# CollectConnections true
+# CollectDirectorDNS false # Varnish 3 only
# CollectSHM true
# CollectESI false
# CollectFetch false
# CollectHCB false
-# CollectSMA false
+# CollectObjects false
+# CollectPurge false # Varnish 2 only
+# CollectSession false
+# CollectSMA false # Varnish 2 only
# CollectSMS false
-# CollectSM false
+# CollectSM false # Varnish 2 only
+# CollectStruct false
# CollectTotals false
+# CollectUptime false
+# CollectVCL false
# CollectWorkers false
# </Instance>
#</Plugin>