Code

collectd.conf(5): Document the per-plugin interval configuration.
[collectd.git] / src / battery.c
index b62ad81df35b4686d7844ccd2d565e38e1365e83..f36172dbcda8b1251b1ab3f36b8932a24a985ef5 100644 (file)
@@ -96,7 +96,7 @@ static int battery_init (void)
 static void battery_submit (const char *plugin_instance, const char *type, double value)
 {
        value_t values[1];
-       value_list_t vl = VALUE_LIST_INIT;
+       value_list_t vl = VALUE_LIST_INIT (plugin_interval);
 
        values[0].gauge = value;
 
@@ -514,7 +514,8 @@ static int battery_read (void)
 
        if (0 == access (battery_acpi_dir, R_OK))
                walk_directory (battery_acpi_dir, battery_read_acpi,
-                               /* user_data = */ NULL);
+                               /* user_data = */ NULL,
+                               /* include hidden */ 0);
        else
        {
                char errbuf[1024];
@@ -529,8 +530,9 @@ static int battery_read (void)
        return (0);
 }
 
-void module_register (void)
+void module_register (plugin_loaddata_t *data)
 {
+       PLUGIN_INIT_INTERVAL (data);
        plugin_register_init ("battery", battery_init);
-       plugin_register_read ("battery", battery_read);
+       plugin_register_read ("battery", battery_read, plugin_interval);
 } /* void module_register */