Code

Merge branch 'collectd-3.11' into collectd-4.0
[collectd.git] / src / collectd.conf.pod
index 45acb68284cd508bab44acc0b6c66c7fa76e770c..879c2c3455e44c51dff2b7d828651ba9ee1c764f 100644 (file)
@@ -6,7 +6,6 @@ collectd.conf - Configuration for the system statistics collection daemon B<coll
 
   BaseDir "/path/to/data/"
   PIDFile "/path/to/pidfile/collectd.pid"
 
   BaseDir "/path/to/data/"
   PIDFile "/path/to/pidfile/collectd.pid"
-  LogFile "/path/to/logfile/collectd.log"
   Server  "123.123.123.123" 12345
 
   LoadPlugin cpu
   Server  "123.123.123.123" 12345
 
   LoadPlugin cpu
@@ -26,13 +25,17 @@ controls which plugins to load. These plugins ultimately define collectd's
 behavior.
 
 The syntax of this config file is similar to the config file of the famos
 behavior.
 
 The syntax of this config file is similar to the config file of the famos
-B<Apache Webserver>. Each line containes either a key-value-pair or a
+B<Apache Webserver>. Each line contains either a key-value-pair or a
 section-start or -end. Empty lines and everything after the hash-symbol `#' is
 ignored. Values are either string, enclosed in double-quotes,
 section-start or -end. Empty lines and everything after the hash-symbol `#' is
 ignored. Values are either string, enclosed in double-quotes,
-(floating-point-)numbers or a boolean extression, i.E<nbsp>e. either B<true> or
+(floating-point-)numbers or a boolean expression, i.E<nbsp>e. either B<true> or
 B<false>. String containing of only alphanumeric characters and underscores do
 not need to be quoted.
 
 B<false>. String containing of only alphanumeric characters and underscores do
 not need to be quoted.
 
+Please note that B<there is a bug> in the library used by collectd to read the
+configfile, that will lead to all lines with trailing whitespaces to be
+ignored. This problem has been solved in collectdE<nbsp>4.0 and later.
+
 =head1 GLOBAL OPTIONS
 
 =over 4
 =head1 GLOBAL OPTIONS
 
 =over 4
@@ -46,7 +49,7 @@ directory for the daemon.
 =item B<LoadPlugin> I<Plugin>
 
 Loads the plugin I<Plugin>. There must be at least one such line or B<collectd>
 =item B<LoadPlugin> I<Plugin>
 
 Loads the plugin I<Plugin>. There must be at least one such line or B<collectd>
-will be mostly useless. The names of the plugins are listed in L<collectd(1)>.
+will be mostly useless.
 
 =item B<PIDFile> I<File>
 
 
 =item B<PIDFile> I<File>
 
@@ -54,17 +57,41 @@ Sets where to write the PID file to. This file is overwritten when it exists
 and deleted when the program ist stopped. Some init-scripts might override this
 setting using the B<-P> commandline option.
 
 and deleted when the program ist stopped. Some init-scripts might override this
 setting using the B<-P> commandline option.
 
-=item B<LogFile> I<File>
+=item B<PluginDir> I<Directory>
+
+Path to the plugins (shared objects) of collectd.
+
+=item B<TypesDB> I<File>
+
+Set the file that contains the data-set descriptions.
+
+=item B<Interval> I<Seconds>
 
 
-Sets the file to write debugging output to. This is only used if compiled with
-debugging enabled. It's ignored otherwise.
+Configures the interval in which to query the read plugins. Obviously smaller
+values lead to a higher system load produces by collectd, while higher values
+lead to more coarse statistics.
+
+=item B<ReadThreads> I<Num>
+
+Number of threads to start for reading plugins. The default value if B<5>, but
+you may want to increase this if you have more than five plugins that take a
+long time to read. Mostly those are plugin that do network-IO. Setting this to
+a value higher than the number of plugins you've loaded is totally useless.
 
 =back
 
 =head1 PLUGIN OPTIONS
 
 
 =back
 
 =head1 PLUGIN OPTIONS
 
-Some Plugins may register own options. These options must be inclosed in a
-C<Plugin>-Section. Which options exist depends on the plugin used:
+Some Plugins may register own options. These options must be enclosed in a
+C<Plugin>-Section. Which options exist depends on the plugin used. Some plugins
+require external configuration, too. The C<apache plugin>, for example,
+required C<mod_status> to be configured in the webserver you're going to
+collect data from. These plugins are listed below as well, even if they don't
+require any configuration within collectd's configfile.
+
+A list of all plugins and a short summary for each plugin can be found in the
+F<README> file shipped with the sourcecode and hopefully binary packets as
+well.
 
 =head2 Plugin C<apache>
 
 
 =head2 Plugin C<apache>
 
@@ -80,6 +107,10 @@ the following snipped to base your Apache config upon:
     </Location>
   </IfModule>
 
     </Location>
   </IfModule>
 
+Since its C<mod_status> module is very similar to Apache's, B<lighttpd> is
+also supported. It introduces a new field, called C<BusyServers>, to count the
+number of currently connected clients. This field is also supported.
+
 The following options are accepted by the C<apache>-plugin:
 
 =over 4
 The following options are accepted by the C<apache>-plugin:
 
 =over 4
@@ -101,7 +132,7 @@ Optional password needed for authentication.
 =item B<CACert> I<File>
 
 File that holds one or more SSL certificates. If you want to use HTTPS you will
 =item B<CACert> I<File>
 
 File that holds one or more SSL certificates. If you want to use HTTPS you will
-possibly need this option. What CA certificates come bundeled with C<libcurl>
+possibly need this option. What CA certificates come bundled with C<libcurl>
 and are checked by default depends on the distribution you use.
 
 =back
 and are checked by default depends on the distribution you use.
 
 =back
@@ -122,6 +153,25 @@ TCP-Port to connect to. Defaults to B<3551>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<cpufreq>
+
+This plugin doesn't have any options. It reads
+F</sys/devices/system/cpu/cpu0/cpufreq/scaling_cur_freq> (for the first CPU
+installed) to get the current CPU frequency. If this file does not exist make
+sure B<cpufreqd> (L<http://cpufreqd.sourceforge.net/>) or a similar tool is
+installed and an "cpu governor" (that's a kernel module) is loaded.
+
+=head2 Plugin C<csv>
+
+=over 4
+
+=item B<DataDir> I<Directory>
+
+Set the directory to store RRD-files under. Per default RRD-files are generated
+beneath the daemon's working directory, i.E<nbsp>e. the B<BaseDir>.
+
+=back
+
 =head2 Plugin C<df>
 
 =over 4
 =head2 Plugin C<df>
 
 =over 4
@@ -142,7 +192,7 @@ Select partitions based on the filesystem type.
 
 Invert the selection: If set to true, all partitions B<except> the ones that
 match any one of the criteria are collected. By default only selected
 
 Invert the selection: If set to true, all partitions B<except> the ones that
 match any one of the criteria are collected. By default only selected
-partitions are collected if a selection is made. If no selection is conifured
+partitions are collected if a selection is made. If no selection is configured
 at all, B<all> partitions are selected.
 
 =back
 at all, B<all> partitions are selected.
 
 =back
@@ -188,8 +238,31 @@ at most B<16384> to prevent typos and dumb mistakes.
 
 =back
 
 
 =back
 
+=head2 Plugin C<exec>
+
+Please make sure to read L<collectd-exec(5)> before using this plugin. It
+contains valuable information on when the executable is executed and the
+output that is expected from it.
+
+=over 4
+
+=item B<Exec> I<User> I<Executable>
+
+Execute the executable I<Executable> as user I<User>.
+
+=back
+
 =head2 Plugin C<hddtemp>
 
 =head2 Plugin C<hddtemp>
 
+To get values from B<hddtemp> collectd connects to B<localhost> (127.0.0.1),
+port B<7634/tcp>. The B<Host> and B<Port> options can be used to change these
+default values, see below. C<hddtemp> has to be running to work correctly. If
+C<hddtemp> is not running timeouts may appear which may interfere with other
+statistics..
+
+The B<hddtemp> homepage can be found at
+L<http://www.guzu.net/linux/hddtemp.php>.
+
 =over 4
 
 =item B<Host> I<Hostname>
 =over 4
 
 =item B<Host> I<Hostname>
@@ -202,8 +275,99 @@ TCP-Port to connect to. Defaults to B<7634>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<interface>
+
+=over 4
+
+=item B<Interface> I<Interface>
+
+Select this interface. By default these interfaces will then be collected. For
+a more detailed description see B<IgnoreSelected> below.
+
+=item B<IgnoreSelected> I<true>|I<false>
+
+If no configuration if given, the B<traffic>-plugin will collect data from
+all interfaces. This may not be practical, especially for loopback- and
+similar interfaces. Thus, you can use the B<Interface>-option to pick the
+interfaces you're interested in. Sometimes, however, it's easier/preferred
+to collect all interfaces I<except> a few ones. This option enables you to
+do that: By setting B<IgnoreSelected> to I<true> the effect of
+B<Interface> is inversed: All selected interfaces are ignored and all
+other interfaces are collected.
+
+=back
+
+=head2 Plugin C<iptables>
+
+=over 4
+
+=item B<Chain> I<Table> I<Chain> [I<Comment|Number> [I<Name>]]
+
+Select the rules to count. If only I<Table> and I<Chain> are given, this plugin
+will collect the counters of all rules which have a comment-match. The comment
+is then used as type-instance.
+
+If I<Comment> or I<Number> is given, only the rule with the matching comment or
+the I<n>th rule will be collected. Again, the comment (or the number) will be
+used as the type-instance.
+
+If I<Name> is supplied, it will be used as the type-instance instead of the
+comment or the number.
+
+=back
+
+=head2 Plugin C<irq>
+
+=over 4
+
+=item B<Irq> I<Irq>
+
+Select this irq. By default these irqs will then be collected. For a more
+detailed description see B<IgnoreSelected> below.
+
+=item B<IgnoreSelected> I<true>|I<false>
+
+If no configuration if given, the B<irq>-plugin will collect data from all
+irqs. This may not be practical, especially if no interrupts happen. Thus, you
+can use the B<Irq>-option to pick the interrupt you're interested in.
+Sometimes, however, it's easier/preferred to collect all interrupts I<except> a
+few ones. This option enables you to do that: By setting B<IgnoreSelected> to
+I<true> the effect of B<Irq> is inversed: All selected interrupts are ignored
+and all other interrupts are collected.
+
+=back
+
+=head2 Plugin C<logfile>
+
+=over 4
+
+=item B<LogLevel> B<debug|info|notice|warning|err>
+
+Sets the log-level. If, for example, set to B<notice>, then all events with
+severity B<notice>, B<warning>, or B<err> will be written to the logfile.
+
+=item B<File> I<File>
+
+Sets the file to write log messages to. The special strings B<stdout> and
+B<stderr> can be used to write to the standard output and standard error
+channels, respectively. This, of course, only makes much sense when collectd is
+running in foreground- or non-daemon-mode.
+
+=back
+
 =head2 Plugin C<mbmon>
 
 =head2 Plugin C<mbmon>
 
+The C<mbmon plugin> uses mbmon to retrieve temperature, voltage, etc.
+
+Be default collectd connects to B<localhost> (127.0.0.1), port B<411/tcp>.  The
+B<Host> and B<Port> options can be used to change these values, see below.
+C<mbmon> has to be running to work correctly. If C<mbmon> is not running
+timeouts may appear which may interfere with other statistics..
+
+C<mbmon> must be run with the -r option ("print TAG and Value format");
+Debian's F</etc/init.d/mbmon> script already does this, other people
+will need to ensure that this is the case.
+
 =over 4
 
 =item B<Host> I<Hostname>
 =over 4
 
 =item B<Host> I<Hostname>
@@ -218,6 +382,20 @@ TCP-Port to connect to. Defaults to B<411>.
 
 =head2 Plugin C<mysql>
 
 
 =head2 Plugin C<mysql>
 
+The C<mysql plugin> requires B<mysqlclient> to be installed. It connects to the
+database when started and keeps the connection up as long as possible. When the
+connection is interrupted for whatever reason it will try to re-connect. The
+plugin logs loud complaints in case anything goes wrong.
+
+This plugin issues C<SHOW STATUS> and evaluates C<Bytes_{received,sent}>,
+C<Com_*> and C<Handler_*> which correspond to F<mysql_octets.rrd>,
+F<mysql_commands-*.rrd> and F<mysql_handler-*.rrd>. Also, the values of
+C<Qcache_*> are put in F<mysql_qcache.rrd> and values of C<Threads_*> are put
+in F<mysql_threads.rrd>. Please refer to the B<MySQL reference manual>,
+I<5.2.4. Server Status Variables> for an explanation of these values.
+
+Use the following options to configure the plugin:
+
 =over 4
 
 =item B<Host> I<Hostname>
 =over 4
 
 =item B<Host> I<Hostname>
@@ -234,7 +412,7 @@ Password needed to log into the database.
 
 =item B<Database> I<Database>
 
 
 =item B<Database> I<Database>
 
-Select this database. Defaults to I<no database> which is a perfecly reasonable
+Select this database. Defaults to I<no database> which is a perfectly reasonable
 option for what this plugin does.
 
 =back
 option for what this plugin does.
 
 =back
@@ -259,13 +437,13 @@ the argument is a multicast address the daemon will join that multicast group.
 If no B<Listen> statement is found the server tries join both, the default IPv6
 multicast group and the default IPv4 multicast group. If no B<Server> statement
 is found the client will try to send data to the IPv6 multicast group first. If
 If no B<Listen> statement is found the server tries join both, the default IPv6
 multicast group and the default IPv4 multicast group. If no B<Server> statement
 is found the client will try to send data to the IPv6 multicast group first. If
-that failes the client will try the IPv4 multicast group.
+that fails the client will try the IPv4 multicast group.
 
 The default IPv6 multicast group is C<ff18::efc0:4a42>. The default IPv4
 multicast group is C<239.192.74.66>.
 
 The optional I<Port> argument sets the port to use. It can either be given
 
 The default IPv6 multicast group is C<ff18::efc0:4a42>. The default IPv4
 multicast group is C<239.192.74.66>.
 
 The optional I<Port> argument sets the port to use. It can either be given
-using a numeric port number or a service name. If the argument is omited the
+using a numeric port number or a service name. If the argument is omitted the
 default port B<25826> is assumed.
 
 =item B<TimeToLive> I<1-255>
 default port B<25826> is assumed.
 
 =item B<TimeToLive> I<1-255>
@@ -275,6 +453,25 @@ multicast, and IPv4 and IPv6 packets. The default is to not change this value.
 That means that multicast packets will be sent with a TTL of C<1> (one) on most
 operating systems.
 
 That means that multicast packets will be sent with a TTL of C<1> (one) on most
 operating systems.
 
+=item B<Forward> I<true|false>
+
+If set to I<true>, write packets that were received via the network plugin to
+the sending sockets. This should only be activated when the B<Listen>- and
+B<Server>-statements differ. Otherwise packets may be send multiple times to
+the same multicast group. While this results in more network traffic than
+necessary it's not a huge problem since the plugin has a duplicate detection,
+so the values will not loop.
+
+=item B<CacheFlush> I<Seconds>
+
+For each host/plugin/type combination the C<network plugin> caches the time of
+the last value being sent or received. Every I<Seconds> seconds the plugin
+searches and removes all entries that are older than I<Seconds> seconds, thus
+freeing the unused memory again. Since this process is somewhat expensive and
+normally doesn't do much, this value should not be too small. The default is
+1800 seconds, but setting this to 86400 seconds (one day) will not do much harm
+either.
+
 =back
 
 =head2 Plugin C<ntpd>
 =back
 
 =head2 Plugin C<ntpd>
@@ -291,6 +488,38 @@ UDP-Port to connect to. Defaults to B<123>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<nut>
+
+=over 4
+
+=item B<UPS> I<upsname>B<@>I<hostname>[B<:>I<port>]
+
+Add a UPS to collect data from. The format is identical to the one accepted by
+L<upsc(8)>.
+
+=back
+
+=head2 Plugin C<perl>
+
+=over 4
+
+=item B<LoadPlugin> I<Plugin>
+
+Loads the Perl plugin I<Plugin>. This does basically the same as B<use> would
+do in a Perl program.
+
+=item B<BaseName> I<Name>
+
+Prepends I<Name>B<::> to all plugin names loaded after this option. This is
+provided for convenience to keep plugin names short.
+
+=item B<IncludeDir> I<Dir>
+
+Adds I<Dir> to the B<@INC> array. This is the same as using the B<-IDir>
+command line option or B<use lib Dir> in the source code.
+
+=back
+
 =head2 Plugin C<ping>
 
 =over 4
 =head2 Plugin C<ping>
 
 =over 4
@@ -306,106 +535,179 @@ Sets the Time-To-Live of generated ICMP packets.
 
 =back
 
 
 =back
 
+=head2 Plugin C<processes>
+
+=over 4
+
+=item B<Process> I<Name>
+
+Select more detailed statistics of processes matching this name. The statistics
+collected for these selected processes are size of the resident segment size
+(RSS), user- and system-time used, number of processes and number of threads,
+and minor and major pagefaults.
+
+=back
+
 =head2 Plugin C<rrdtool>
 
 =head2 Plugin C<rrdtool>
 
+You can use the settings B<StepSize>, B<HeartBeat>, B<RRARows>, and B<XFF> to
+finetune your RRD-files. Please read L<rrdcreate(1)> if you encounter problems
+using these settings. If you don't want to dive into the depths of RRDTool, you
+can safely ignore these settings.
+
 =over 4
 
 =over 4
 
+=item B<DataDir> I<Directory>
+
+Set the directory to store RRD-files under. Per default RRD-files are generated
+beneath the daemon's working directory, i.E<nbsp>e. the B<BaseDir>.
+
+=item B<StepSize> I<Seconds>
+
+Sets the stepsize of newly created RRD-files. Ideally (and per default) this
+setting is identical to the global B<Interval>-option and should not be
+smaller. If unsure, don't set this option.
+
+=item B<HeartBeat> I<Seconds>
+
+Sets the heartbeat of newly created RRD-files. Ideally this setting is bigger
+than the B<Interval>-setting, by default it's twice the B<Interval>-setting. If
+unsure, don't set this option.
+
+=item B<RRARows> I<NumRows>
+
+The C<rrdtool plugin> calculates the number of PDPs per CDP based on the
+B<StepSize>, this setting and a timespan. This plugin creates RRD-files with
+three times five RRAs, i. e. five RRAs with the CFs B<MIN>, B<AVERAGE>, and
+B<MAX>. The five RRAs are optimized for graphs covering one hour, one day, one
+week, one month, and one year.
+
+So for each timespan, it calculates how many PDPs need to be consolidated into
+one CDP by calculating:
+  number of PDPs = timespan / (stepsize * rrarows)
+
+Bottom line is, set this no smaller than the width of you graphs in pixels. The
+default is 1200.
+
+=item B<RRATimespan> I<Seconds>
+
+Adds an RRA-timespan, given in seconds. Use this option multiple times to have
+more then one RRA. If this option is never used, the built-in default of (3600,
+86400, 604800, 2678400, 31622400) is used.
+
+For more information on how RRA-sizes are calculated see B<RRARows> above.
+
+=item B<XFF> I<Factor>
+
+Set the "XFiles Factor". The default is 0.1. If unsure, don't set this option.
+
+=item B<CacheFlush> I<Seconds>
+
+When the C<rrdtool plugin> uses a cache (by setting B<CacheTimeout>, see below)
+it writes all values for a certain RRD-file if the oldest value is older than
+(or equal to) the number of seconds specified. If some RRD-file is not updated
+anymore for some reason (the computer was shut down, the network is broken,
+etc.) some values may still be in the cache. If B<CacheFlush> is set, then the
+entire cache is searched for entries older than B<CacheTimeout> seconds and
+written to disk every I<Seconds> seconds. Since this is kind of expensive and
+does nothing under normal circumstances, this value should not be too small.
+900 seconds might be a good value, though setting this to 7200 seconds doesn't
+normally do much harm either.
+
 =item B<CacheTimeout> I<Seconds>
 
 =item B<CacheTimeout> I<Seconds>
 
-If this option is set to a value greater than zero, the C<rrdtool>-plugin will
-write values every I<Seconds> seconds to the RRD-files. Writing multiple values
-at once reduces IO-operations and thus lessens the load produced by updating
-the files. The tradeoff is that the graphs kind of "drag behind" and that more
-memory is used.
+If this option is set to a value greater than zero, the C<rrdtool plugin> will
+save values in a cache, as described above. Writing multiple values at once
+reduces IO-operations and thus lessens the load produced by updating the files.
+The tradeoff is that the graphs kind of "drag behind" and that more memory is
+used.
 
 =back
 
 =head2 Plugin C<sensors>
 
 
 =back
 
 =head2 Plugin C<sensors>
 
+The C<sensors plugin> uses B<lm_sensors> to retrieve sensor-values. This means
+that all the needed modules have to be loaded and lm_sensors has to be
+configured (most likely by editing F</etc/sensors.conf>. Read
+L<sensors.conf(5)> for details.
+
+The B<lm_sensors> homepage can be found at
+L<http://secure.netroedge.com/~lm78/>.
+
 =over 4
 
 =over 4
 
-=item B<ExtendedSensorNaming> I<true>|I<false>
-
-If set to I<true> this option switches on the extended sensors and RRD-files
-naming. This option exists to preserve backwards compatibility. It is
-recommended that you set this option to I<true>. The default is I<false> to
-maintain compatibility only.
-
-Sensors get names like I<chip-bus-address/type-feature> (e.g.
-I<it8712-isa-0290/voltage-in1>) and RRD files are therefore stored in a
-standalone directory inside the B<DataDir> directory and get names like
-I<lm_sensors-chip-bus-address/type-feature.rrd> (e.g.
-I<lm_sensors-it8712-isa-0290/voltage-in1.rrd>).
-
-The B<ExtendedSensorNaming> option breaks the compatibility with previous
-sensors and RRD files naming and the place where RRDs are stored. If you turn
-it on, the plugin will create new RRD files in a standalone directory inside
-the B<DataDir> directory and without previous history. You can rename ``old''
-RRD-files to preserve already collected statistics, because the file layout
-hasn't changed. If you have two chips of the same type, you need to use
-B<ExtendedSensorNaming> in order to collect information from both chips.
-
-If not set or set to I<false>, the extended naming is not active. Sensors get
-names like I<chip-feature> (e.g. I<it8712-in1>) and RRD files are stored in the
-main B<DataDir> directory and get names like I<sensors-chip-feature.rrd> (e.g.
-I<sensors-it8712-in1.rrd>).  You simply continue using the plugin the old way
-and additionally also getting data for newly added sensors in this mode.
-
-=item B<Sensor> I<chip-feature> or B<Sensor> I<chip-bus-address/type-feature>
-
-Both option modes select the name of the sensor which you want to collect.
-The naming scheme is dependent on the state of the B<ExtendedSensorNaming>
-option (see previous option). Both option modes can also deselect the
-sensor according to the B<IgnoreSelected> option (see below).
-
-For example the option "B<Sensor> I<it8712-in1>" will cause the collectd
-to gather data for the voltage sensor I<in1> of the I<it8712> chip in case
-of the B<ExtendedSensorNaming> option is set to I<false>.
-
-And likewise the option "B<Sensor> I<it8712-isa-0290/voltage-in1>" will
-cause the collectd to gather data for the voltage sensor I<in1> of the I<it8712>
-on the isa bus at the address 0290 in case of the B<ExtendedSensorNaming>
-option set to I<true>.
+=item B<Sensor> I<chip-bus-address/type-feature>
+
+Selects the name of the sensor which you want to collect or ignore, depending
+on the B<IgnoreSelected> below. For example, the option "B<Sensor>
+I<it8712-isa-0290/voltage-in1>" will cause collectd to gather data for the
+voltage sensor I<in1> of the I<it8712> on the isa bus at the address 0290.
 
 =item B<IgnoreSelected> I<true>|I<false>
 
 
 =item B<IgnoreSelected> I<true>|I<false>
 
-If no configuration if given, the B<sensors>-plugin will collect data from
-all sensors. This may not be practical, especially for uninteresting sensors.
-Thus, you can use the B<Sensor>-option to pick the sensors you're
-interested in. Sometimes, however, it's easier/prefered to collect all
-sensors I<except> a few ones. This option enables you to
-do that: By setting B<IgnoreSelected> to I<true> the effect of
-B<Sensor> is inversed: All selected sensors are ignored and all
-other sensors are collected.
+If no configuration if given, the B<sensors>-plugin will collect data from all
+sensors. This may not be practical, especially for uninteresting sensors.
+Thus, you can use the B<Sensor>-option to pick the sensors you're interested
+in. Sometimes, however, it's easier/preferred to collect all sensors I<except> a
+few ones. This option enables you to do that: By setting B<IgnoreSelected> to
+I<true> the effect of B<Sensor> is inversed: All selected sensors are ignored
+and all other sensors are collected.
+
+=back
+
+=head2 Plugin C<syslog>
 
 
-back
+=over 4
+
+=item B<LogLevel> B<debug|info|notice|warning|err>
+
+Sets the log-level. If, for example, set to B<notice>, then all events with
+severity B<notice>, B<warning>, or B<err> will be submitted to the
+syslog-daemon.
 
 =back
 
 
 =back
 
-=head2 Plugin C<traffic>
+=head2 Plugin C<unixsock>
 
 =over 4
 
 
 =over 4
 
-=item B<Interface> I<Interface>
+=item B<SocketFile> I<Path>
 
 
-Select this interface. By default these interfaces will then be collected. For a more detailed description see B<IgnoreSelected> below.
+Sets the socket-file which is to be created.
 
 
-=item B<IgnoreSelected> I<true>|I<false>
+=item B<SocketGroup> I<Group>
 
 
-If no configuration if given, the B<traffic>-plugin will collect data from
-all interfaces. This may not be practical, especially for loopback- and
-similar interfaces. Thus, you can use the B<Interface>-option to pick the
-interfaces you're interested in. Sometimes, however, it's easier/prefered
-to collect all interfaces I<except> a few ones. This option enables you to
-do that: By setting B<IgnoreSelected> to I<true> the effect of
-B<Interface> is inversed: All selected interfaces are ignored and all
-other interfaces are collected.
+If running as root change the group of the UNIX-socket after it has been 
+created. Defaults to B<collectd>.
+
+=item B<SocketPerms> I<Permissions>
+
+Change the file permissions of the UNIX-socket after it has been created. The
+permissions must be given as a numeric, octal value as you would pass to
+L<chmod(1)>. Defaults to B<0770>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<vserver>
+
+This plugin doesn't have any options. B<VServer> support is only available for
+Linux. It cannot yet be found in a vanilla kernel, though. To make use of this
+plugin you need a kernel that has B<VServer> support built in, i.E<nbsp>e. you
+need to apply the patches and compile your own kernel, which will then provide
+the F</proc/virtual> filesystem that is required by this plugin.
+
+The B<VServer> homepage can be found at L<http://linux-vserver.org/>.
+
 =head1 SEE ALSO
 
 =head1 SEE ALSO
 
-L<collectd(1)>
+L<collectd(1)>,
+L<collectd-exec(5)>,
+L<collectd-unixsock(5)>,
+L<hddtemp(8)>,
+L<kstat(3KSTAT)>,
+L<mbmon(1)>,
+L<rrdtool(1)>,
+L<sensors(1)>
 
 =head1 AUTHOR
 
 
 =head1 AUTHOR