5ebbf7f214c3ab6aeeac97f97e06da52e30d00c8
1 <Plugin snmp>
2 #
3 # IF-MIB
4 # Interface statistics using the IF-MIB
5 #
6 <Data "ifmib_if_octets32">
7 Type "if_octets"
8 Table true
9 Instance "IF-MIB::ifDescr"
10 Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
11 </Data>
12 <Data "ifmib_if_octets64">
13 Type "if_octets"
14 Table true
15 Instance "IF-MIB::ifName"
16 Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets"
17 </Data>
18 <Data "ifmib_if_packets32">
19 Type "if_packets"
20 Table true
21 Instance "IF-MIB::ifDescr"
22 Values "IF-MIB::ifInUcastPkts" "IF-MIB::ifOutUcastPkts"
23 </Data>
24 <Data "ifmib_if_packets64">
25 Type "if_packets"
26 Table true
27 Instance "IF-MIB::ifName"
28 Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts"
29 </Data>
30 <Data "ifmib_if_errors32">
31 Type "if_errors"
32 Table true
33 Instance "IF-MIB::ifDescr"
34 Values "IF-MIB::ifInErrors" "IF-MIB::ifOutErrors"
35 </Data>
36 <Data "ifmib_if_errors64">
37 Type "if_errors"
38 Table true
39 Instance "IF-MIB::ifName"
40 Values "IF-MIB::ifHCInErrors" "IF-MIB::ifHCOutErrors"
41 </Data>
43 #
44 # UPS-MIB
45 # Statistics about your UPS using the UPS-MIB from the RFC1628.
46 #
47 <Data "upsmib_charge_battery">
48 Type "percent"
49 Table false
50 Instance "charge-battery"
51 Values ".1.3.6.1.2.1.33.1.2.4.0"
52 </Data>
53 <Data "upsmib_voltage_battery">
54 Type "voltage"
55 Table false
56 Instance "battery"
57 Values ".1.3.6.1.2.1.33.1.2.5.0"
58 </Data>
59 <Data "upsmib_voltage_input">
60 Type "voltage"
61 Table true
62 InstancePrefix "input"
63 Values ".1.3.6.1.2.1.33.1.3.3.1.3"
64 </Data>
65 <Data "upsmib_voltage_output">
66 Type "voltage"
67 Table true
68 InstancePrefix "output"
69 Values ".1.3.6.1.2.1.33.1.4.4.1.2"
70 </Data>
71 <Data "upsmib_voltage_bypass">
72 Type "voltage"
73 Table true
74 InstancePrefix "bypass"
75 Values ".1.3.6.1.2.1.33.1.5.3.1.2"
76 </Data>
77 <Data "upsmib_current_battery">
78 Type "current"
79 Table false
80 Instance "battery"
81 Values ".1.3.6.1.2.1.33.1.2.6.0"
82 </Data>
83 <Data "upsmib_current_input">
84 Type "current"
85 Table true
86 InstancePrefix "input"
87 Values ".1.3.6.1.2.1.33.1.3.3.1.4"
88 </Data>
89 <Data "upsmib_current_output">
90 Type "current"
91 Table true
92 InstancePrefix "output"
93 Values ".1.3.6.1.2.1.33.1.4.4.1.3"
94 </Data>
95 <Data "upsmib_current_bypass">
96 Type "current"
97 Table true
98 InstancePrefix "bypass"
99 Values ".1.3.6.1.2.1.33.1.5.3.1.3"
100 </Data>
101 <Data "upsmib_temperature_battery">
102 Type "temperature"
103 Table false
104 Instance "battery"
105 Values ".1.3.6.1.2.1.33.1.2.7.0"
106 </Data>
108 #
109 # Riello UPS
110 # Temperatures for UPSes by Riello, <http://www.riello-ups.de/>
111 #
112 <Data "riello_temperature_system">
113 Type "temperature"
114 Table false
115 Instance "system"
116 Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0"
117 </Data>
118 <Data "riello_temperature_rectifier">
119 Type "temperature"
120 Table false
121 Instance "rectifier"
122 Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0"
123 </Data>
124 <Data "riello_temperature_inverter">
125 Type "temperature"
126 Table false
127 Instance "inverter"
128 Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0"
129 </Data>
131 #
132 # NetApp
133 # Some simple statistics of storage systems by NetApp.
134 #
135 <Data "netapp_cpu_system">
136 Type "cpu"
137 Table false
138 Instance "system"
139 Values ".1.3.6.1.4.1.789.1.2.1.2.0"
140 </Data>
141 <Data "netapp_cpu_idle">
142 Type "cpu"
143 Table false
144 Instance "idle"
145 Values ".1.3.6.1.4.1.789.1.2.1.4.0"
146 </Data>
147 <Data "netapp_if_octets">
148 Type "if_octets"
149 Table false
150 Instance "net"
151 Values ".1.3.6.1.4.1.789.1.2.2.12.0" ".1.3.6.1.4.1.789.1.2.2.14.0"
152 </Data>
154 #
155 # Juniper SSL
156 # Some stats of an SSL-appliance by Juniper.
157 #
158 <Data "juniperssl_users_web">
159 Type "users"
160 Table false
161 Instance "web"
162 Values ".1.3.6.1.4.1.12532.2.0"
163 </Data>
164 <Data "juniperssl_users_mail">
165 Type "users"
166 Table false
167 Instance "mail"
168 Values ".1.3.6.1.4.1.12532.3.0"
169 </Data>
170 <Data "juniperssl_percent_logfull">
171 Type "percent"
172 Table false
173 Instance "logfull"
174 Values ".1.3.6.1.4.1.12532.1.0"
175 </Data>
176 <Data "juniperssl_percent_diskfull">
177 Type "percent"
178 Table false
179 Instance "diskfull"
180 Values ".1.3.6.1.4.1.12532.25.0"
181 </Data>
184 #
185 # WuT
186 # Some thermometers and digital IO devices from WuT
187 # <http://www.wut.de/>
188 #
189 <Data "wut_an8graph">
190 Type "temperature"
191 Table true
192 Instance ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2"
193 Values ".1.3.6.1.4.1.5040.1.2.6.1.4.1.1"
194 Scale 0.1
195 </Data>
196 <Data "wut_an2graph">
197 Type "temperature"
198 Table true
199 Instance ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2"
200 Values ".1.3.6.1.4.1.5040.1.2.7.1.4.1.1"
201 Scale 0.1
202 </Data>
203 <Data "wut_an1graph">
204 Type "temperature"
205 Table true
206 Instance ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2"
207 Values ".1.3.6.1.4.1.5040.1.2.8.1.4.1.1"
208 Scale 0.1
209 </Data>
210 <Data "wut_thermo8">
211 Type "temperature"
212 Table true
213 Instance ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2"
214 Values ".1.3.6.1.4.1.5040.1.2.1.1.4.1.1"
215 Scale 0.1
216 </Data>
217 <Data "wut_thermo2">
218 Type "temperature"
219 Table true
220 Instance ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2"
221 Values ".1.3.6.1.4.1.5040.1.2.2.1.4.1.1"
222 Scale 0.1
223 </Data>
224 <Data "wut_thermo1">
225 Type "temperature"
226 Table true
227 Instance ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2"
228 Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1"
229 Scale 0.1
230 </Data>
232 #
233 # Infratec
234 # Rack monitoring devices by Infratec, <http://www.infratec-ag.de/>
235 #
236 # Model H2-17
237 <Data "infratec_h2_17_temperature">
238 Type "temperature"
239 Table true
240 Instance ".1.3.6.1.4.1.4519.10.4.1.1.2"
241 Values ".1.3.6.1.4.1.4519.10.4.1.1.3"
242 </Data>
243 <Data "infratec_h2_17_humidity">
244 Type "humidity"
245 Table true
246 Instance ".1.3.6.1.4.1.4519.10.5.1.1.2"
247 Values ".1.3.6.1.4.1.4519.10.5.1.1.3"
248 </Data>
249 <Data "infratec_h2_17_voltage">
250 Type "voltage"
251 Table true
252 InstancePrefix "input"
253 Values ".1.3.6.1.4.1.4519.10.6.1.1.3"
254 </Data>
255 # Model H2-30
256 <Data "infratec_h2_30_temperature">
257 Type "temperature"
258 Table true
259 Instance ".1.3.6.1.4.1.1909.10.4.1.1.2"
260 Values ".1.3.6.1.4.1.1909.10.4.1.1.3"
261 </Data>
262 <Data "infratec_h2_30_humidity">
263 Type "humidity"
264 Table true
265 Instance ".1.3.6.1.4.1.1909.10.5.1.1.2"
266 Values ".1.3.6.1.4.1.1909.10.5.1.1.3"
267 </Data>
268 <Data "infratec_h2_30_voltage">
269 Type "voltage"
270 Table true
271 InstancePrefix "input"
272 Values ".1.3.6.1.4.1.1909.10.6.1.1.3"
273 </Data>
274 </Plugin>