1 <Plugin snmp>
2 #
3 # IF-MIB
4 # Interface statistics using the IF-MIB
5 #
6 <Data "ifmib_if_octets32">
7 Type "if_octets"
8 Table true
9 Instance "IF-MIB::ifDescr"
10 Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
11 </Data>
12 <Data "ifmib_if_octets64">
13 Type "if_octets"
14 Table true
15 Instance "IF-MIB::ifName"
16 Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets"
17 </Data>
18 <Data "ifmib_if_packets32">
19 Type "if_packets"
20 Table true
21 Instance "IF-MIB::ifDescr"
22 Values "IF-MIB::ifInUcastPkts" "IF-MIB::ifOutUcastPkts"
23 </Data>
24 <Data "ifmib_if_packets64">
25 Type "if_packets"
26 Table true
27 Instance "IF-MIB::ifName"
28 Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts"
29 </Data>
30 <Data "ifmib_if_errors32">
31 Type "if_errors"
32 Table true
33 Instance "IF-MIB::ifDescr"
34 Values "IF-MIB::ifInErrors" "IF-MIB::ifOutErrors"
35 </Data>
36 <Data "ifmib_if_errors64">
37 Type "if_errors"
38 Table true
39 Instance "IF-MIB::ifName"
40 Values "IF-MIB::ifHCInErrors" "IF-MIB::ifHCOutErrors"
41 </Data>
43 #
44 # UPS-MIB
45 # Statistics about your UPS using the UPS-MIB from the RFC1628.
46 #
47 # Battery branch
48 <Data "upsmib_timeleft_battery">
49 Type "timeleft"
50 Table false
51 Instance "battery"
52 Values ".1.3.6.1.2.1.33.1.2.3.0"
53 </Data>
54 <Data "upsmib_charge_battery">
55 Type "percent"
56 Table false
57 Instance "charge-battery"
58 Values ".1.3.6.1.2.1.33.1.2.4.0"
59 </Data>
60 <Data "upsmib_voltage_battery">
61 Type "voltage"
62 Table false
63 Instance "battery"
64 Values ".1.3.6.1.2.1.33.1.2.5.0"
65 Scale 0.1
66 </Data>
67 <Data "upsmib_current_battery">
68 Type "current"
69 Table false
70 Instance "battery"
71 Values ".1.3.6.1.2.1.33.1.2.6.0"
72 Scale 0.1
73 </Data>
74 <Data "upsmib_temperature_battery">
75 Type "temperature"
76 Table false
77 Instance "battery"
78 Values ".1.3.6.1.2.1.33.1.2.7.0"
79 </Data>
80 # Input branch
81 <Data "upsmib_frequency_input">
82 Type "frequency"
83 Table true
84 InstancePrefix "input"
85 Values ".1.3.6.1.2.1.33.1.3.3.1.2"
86 Scale 0.1
87 </Data>
88 <Data "upsmib_voltage_input">
89 Type "voltage"
90 Table true
91 InstancePrefix "input"
92 Values ".1.3.6.1.2.1.33.1.3.3.1.3"
93 </Data>
94 <Data "upsmib_current_input">
95 Type "current"
96 Table true
97 InstancePrefix "input"
98 Values ".1.3.6.1.2.1.33.1.3.3.1.4"
99 Scale 0.1
100 </Data>
101 <Data "upsmib_power_input">
102 Type "power"
103 Table true
104 InstancePrefix "input"
105 Values ".1.3.6.1.2.1.33.1.3.3.1.5"
106 </Data>
107 # Output branch
108 <Data "upsmib_frequency_output">
109 Type "frequency"
110 Table false
111 Instance "output"
112 Values ".1.3.6.1.2.1.33.1.4.2.0"
113 Scale 0.1
114 </Data>
115 <Data "upsmib_voltage_output">
116 Type "voltage"
117 Table true
118 InstancePrefix "output"
119 Values ".1.3.6.1.2.1.33.1.4.4.1.2"
120 </Data>
121 <Data "upsmib_current_output">
122 Type "current"
123 Table true
124 InstancePrefix "output"
125 Values ".1.3.6.1.2.1.33.1.4.4.1.3"
126 Scale 0.1
127 </Data>
128 <Data "upsmib_power_output">
129 Type "power"
130 Table true
131 InstancePrefix "output"
132 Values ".1.3.6.1.2.1.33.1.4.4.1.4"
133 </Data>
134 <Data "upsmib_load_output">
135 Type "percent"
136 Table true
137 InstancePrefix "load-output"
138 Values ".1.3.6.1.2.1.33.1.4.4.1.5"
139 </Data>
140 # Bypass branch
141 <Data "upsmib_frequency_bypass">
142 Type "frequency"
143 Table false
144 Instance "output"
145 Values ".1.3.6.1.2.1.33.1.5.1.0"
146 Scale 0.1
147 </Data>
148 <Data "upsmib_voltage_bypass">
149 Type "voltage"
150 Table true
151 InstancePrefix "bypass"
152 Values ".1.3.6.1.2.1.33.1.5.3.1.2"
153 </Data>
154 <Data "upsmib_current_bypass">
155 Type "current"
156 Table true
157 InstancePrefix "bypass"
158 Values ".1.3.6.1.2.1.33.1.5.3.1.3"
159 Scale 0.1
160 </Data>
161 <Data "upsmib_power_bypass">
162 Type "power"
163 Table true
164 InstancePrefix "bypass"
165 Values ".1.3.6.1.2.1.33.1.5.3.1.4"
166 </Data>
167 # Special definitions for broken UPSes
168 <Data "upsmib_voltage_battery_unscaled">
169 Type "voltage"
170 Table false
171 Instance "battery"
172 Values ".1.3.6.1.2.1.33.1.2.5.0"
173 </Data>
174 <Data "upsmib_current_input_unscaled">
175 Type "current"
176 Table true
177 InstancePrefix "input"
178 Values ".1.3.6.1.2.1.33.1.3.3.1.4"
179 </Data>
180 <Data "upsmib_current_output_unscaled">
181 Type "current"
182 Table true
183 InstancePrefix "output"
184 Values ".1.3.6.1.2.1.33.1.4.4.1.3"
185 </Data>
187 #
188 # Riello UPS
189 # Temperatures for UPSes by Riello, <http://www.riello-ups.de/>
190 #
191 <Data "riello_temperature_system">
192 Type "temperature"
193 Table false
194 Instance "system"
195 Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0"
196 </Data>
197 <Data "riello_temperature_rectifier">
198 Type "temperature"
199 Table false
200 Instance "rectifier"
201 Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0"
202 </Data>
203 <Data "riello_temperature_inverter">
204 Type "temperature"
205 Table false
206 Instance "inverter"
207 Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0"
208 </Data>
210 #
211 # PowerPlus UPS, manufactured by Gamatronic, <http://www.gamatronic.com/>,
212 # distributed in Germany by AdPoS, <http://adpos-usv.de/>
213 #
214 # Global inputs
215 <Data "powerplus_voltage_input">
216 Type "voltage"
217 Table true
218 InstancePrefix "input"
219 Values ".1.3.6.1.4.1.6050.5.4.1.1.2"
220 </Data>
221 <Data "powerplus_current_input">
222 Type "current"
223 Table true
224 InstancePrefix "input"
225 Values ".1.3.6.1.4.1.6050.5.4.1.1.3"
226 </Data>
227 <Data "powerplus_power_apparent_input">
228 Type "power"
229 Table true
230 InstancePrefix "apparent-input"
231 Values ".1.3.6.1.4.1.6050.5.4.1.1.4"
232 Scale 100.0
233 </Data>
234 <Data "powerplus_power_active_input">
235 Type "power"
236 Table true
237 InstancePrefix "active-input"
238 Values ".1.3.6.1.4.1.6050.5.4.1.1.5"
239 Scale 100.0
240 </Data>
241 <Data "powerplus_performance_factor_input">
242 Type "percent"
243 Table true
244 InstancePrefix "performance_factor-input"
245 Values ".1.3.6.1.4.1.6050.5.4.1.1.6"
246 </Data>
247 # Global outputs
248 <Data "powerplus_voltage_output">
249 Type "voltage"
250 Table true
251 InstancePrefix "output"
252 Values ".1.3.6.1.4.1.6050.5.5.1.1.2"
253 </Data>
254 <Data "powerplus_current_output">
255 Type "current"
256 Table true
257 InstancePrefix "output"
258 Values ".1.3.6.1.4.1.6050.5.5.1.1.3"
259 </Data>
260 <Data "powerplus_power_apparent_output">
261 Type "power"
262 Table true
263 InstancePrefix "apparent-output"
264 Values ".1.3.6.1.4.1.6050.5.5.1.1.4"
265 Scale 100.0
266 </Data>
267 <Data "powerplus_power_active_output">
268 Type "power"
269 Table true
270 InstancePrefix "active-output"
271 Values ".1.3.6.1.4.1.6050.5.5.1.1.5"
272 Scale 100.0
273 </Data>
274 <Data "powerplus_load_level_output">
275 Type "percent"
276 Table true
277 InstancePrefix "load_level-output"
278 Values ".1.3.6.1.4.1.6050.5.5.1.1.6"
279 </Data>
280 <Data "powerplus_active_load_level_output">
281 Type "percent"
282 Table true
283 InstancePrefix "active_load_level-output"
284 Values ".1.3.6.1.4.1.6050.5.5.1.1.7"
285 </Data>
286 <Data "powerplus_performance_factor_output">
287 Type "percent"
288 Table true
289 InstancePrefix "performance_factor-output"
290 Values ".1.3.6.1.4.1.6050.5.5.1.1.8"
291 </Data>
292 # Global DC
293 <Data "powerplus_global_dc_positive">
294 Type "voltage"
295 Table false
296 Instance "dc_positive-global"
297 Values ".1.3.6.1.4.1.6050.5.6.1.0"
298 </Data>
299 <Data "powerplus_global_dc_negative">
300 Type "voltage"
301 Table false
302 Instance "dc_negative-global"
303 Values ".1.3.6.1.4.1.6050.5.6.2.0"
304 </Data>
305 <Data "powerplus_global_dc_total">
306 Type "voltage"
307 Table false
308 Instance "dc_total-global"
309 Values ".1.3.6.1.4.1.6050.5.6.3.0"
310 </Data>
312 #
313 # NetApp
314 # Some simple statistics of storage systems by NetApp.
315 #
316 <Data "netapp_cpu_system">
317 Type "cpu"
318 Table false
319 Instance "system"
320 Values ".1.3.6.1.4.1.789.1.2.1.2.0"
321 </Data>
322 <Data "netapp_cpu_idle">
323 Type "cpu"
324 Table false
325 Instance "idle"
326 Values ".1.3.6.1.4.1.789.1.2.1.4.0"
327 </Data>
328 <Data "netapp_if_octets">
329 Type "if_octets"
330 Table false
331 Instance "net"
332 Values ".1.3.6.1.4.1.789.1.2.2.12.0" ".1.3.6.1.4.1.789.1.2.2.14.0"
333 </Data>
335 #
336 # Juniper SSL
337 # Some stats of an SSL-appliance by Juniper.
338 #
339 <Data "juniperssl_users_web">
340 Type "users"
341 Table false
342 Instance "web"
343 Values ".1.3.6.1.4.1.12532.2.0"
344 </Data>
345 <Data "juniperssl_users_mail">
346 Type "users"
347 Table false
348 Instance "mail"
349 Values ".1.3.6.1.4.1.12532.3.0"
350 </Data>
351 <Data "juniperssl_percent_logfull">
352 Type "percent"
353 Table false
354 Instance "logfull"
355 Values ".1.3.6.1.4.1.12532.1.0"
356 </Data>
357 <Data "juniperssl_percent_diskfull">
358 Type "percent"
359 Table false
360 Instance "diskfull"
361 Values ".1.3.6.1.4.1.12532.25.0"
362 </Data>
365 #
366 # WuT
367 # Some thermometers and digital IO devices from WuT
368 # <http://www.wut.de/>
369 #
370 <Data "wut_an8graph">
371 Type "temperature"
372 Table true
373 Instance ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2"
374 Values ".1.3.6.1.4.1.5040.1.2.6.1.4.1.1"
375 Scale 0.1
376 </Data>
377 <Data "wut_an2graph">
378 Type "temperature"
379 Table true
380 Instance ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2"
381 Values ".1.3.6.1.4.1.5040.1.2.7.1.4.1.1"
382 Scale 0.1
383 </Data>
384 <Data "wut_an1graph">
385 Type "temperature"
386 Table true
387 Instance ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2"
388 Values ".1.3.6.1.4.1.5040.1.2.8.1.4.1.1"
389 Scale 0.1
390 </Data>
391 <Data "wut_thermo8">
392 Type "temperature"
393 Table true
394 Instance ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2"
395 Values ".1.3.6.1.4.1.5040.1.2.1.1.4.1.1"
396 Scale 0.1
397 </Data>
398 <Data "wut_thermo2">
399 Type "temperature"
400 Table true
401 Instance ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2"
402 Values ".1.3.6.1.4.1.5040.1.2.2.1.4.1.1"
403 Scale 0.1
404 </Data>
405 <Data "wut_thermo1">
406 Type "temperature"
407 Table true
408 Instance ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2"
409 Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1"
410 Scale 0.1
411 </Data>
413 #
414 # Infratec
415 # Rack monitoring devices by Infratec, <http://www.infratec-ag.de/>
416 #
417 # Model H2-17
418 <Data "infratec_h2_17_temperature">
419 Type "temperature"
420 Table true
421 Instance ".1.3.6.1.4.1.4519.10.4.1.1.2"
422 Values ".1.3.6.1.4.1.4519.10.4.1.1.3"
423 </Data>
424 <Data "infratec_h2_17_humidity">
425 Type "humidity"
426 Table true
427 Instance ".1.3.6.1.4.1.4519.10.5.1.1.2"
428 Values ".1.3.6.1.4.1.4519.10.5.1.1.3"
429 </Data>
430 <Data "infratec_h2_17_voltage">
431 Type "voltage"
432 Table true
433 InstancePrefix "input"
434 Values ".1.3.6.1.4.1.4519.10.6.1.1.3"
435 </Data>
436 # Model H2-30
437 <Data "infratec_h2_30_temperature">
438 Type "temperature"
439 Table true
440 Instance ".1.3.6.1.4.1.1909.10.4.1.1.2"
441 Values ".1.3.6.1.4.1.1909.10.4.1.1.3"
442 </Data>
443 <Data "infratec_h2_30_humidity">
444 Type "humidity"
445 Table true
446 Instance ".1.3.6.1.4.1.1909.10.5.1.1.2"
447 Values ".1.3.6.1.4.1.1909.10.5.1.1.3"
448 </Data>
449 <Data "infratec_h2_30_voltage">
450 Type "voltage"
451 Table true
452 InstancePrefix "input"
453 Values ".1.3.6.1.4.1.1909.10.6.1.1.3"
454 </Data>
456 #
457 # Mikrotik RouterBoards
458 #
459 # Wireless statistics: station mode
460 <Data "mikrotik_wl_sta_bitrate_tx">
461 tYPE "Bitrate"
462 Table true
463 InstancePrefix "st-tx-"
464 Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
465 Values ".1.3.6.1.4.1.14988.1.1.1.1.1.2"
466 </Data>
468 <Data "mikrotik_wl_sta_bitrate_rx">
469 Type "bitrate"
470 Table true
471 InstancePrefix "st-rx-"
472 Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
473 Values ".1.3.6.1.4.1.14988.1.1.1.1.1.3"
474 </Data>
476 <Data "mikrotik_wl_sta_signal">
477 Type "signal_power"
478 Table true
479 InstancePrefix "st-"
480 Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
481 Values ".1.3.6.1.4.1.14988.1.1.1.1.1.4"
482 </Data>
484 # Wireless statistics: AP mode / registration table
485 <Data "mikrotik_wl_reg_signal">
486 Type "signal_power"
487 Table true
488 InstancePrefix "ap-"
489 Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
490 Values ".1.3.6.1.4.1.14988.1.1.1.2.1.3"
491 </Data>
493 <Data "mikrotik_wl_reg_octets">
494 Type "if_octets"
495 Table true
496 InstancePrefix "ap-"
497 Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
498 Values ".1.3.6.1.4.1.14988.1.1.1.2.1.5" ".1.3.6.1.4.1.14988.1.1.1.2.1.4"
499 </Data>
501 <Data "mikrotik_wl_reg_packets">
502 Type "if_packets"
503 Table true
504 InstancePrefix "ap-"
505 Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
506 Values ".1.3.6.1.4.1.14988.1.1.1.2.1.7" ".1.3.6.1.4.1.14988.1.1.1.2.1.6"
507 </Data>
509 <Data "mikrotik_wl_reg_bitrate_tx">
510 Type "bitrate"
511 Table true
512 InstancePrefix "ap-tx-"
513 Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
514 Values ".1.3.6.1.4.1.14988.1.1.1.2.1.8"
515 </Data>
517 <Data "mikrotik_wl_reg_bitrate_rx">
518 Type "bitrate"
519 Table true
520 InstancePrefix "ap-rx-"
521 Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
522 Values ".1.3.6.1.4.1.14988.1.1.1.2.1.9"
523 </Data>
524 </Plugin>